Samsung DVE50M7450P/AC 用户手册

下载
页码 168
Installation
English  21 
4-wire system
A
B
C
D
F
E
A.  External ground connector
B.  Green or bare copper wire of power 
cord
C. 
3
/
4
” (1.9 cm) UL-listed strain relief
D.  Center silver-colored terminal block 
screw
E.  Neutral grounding wire (white)
F.  Neutral wire (white or center wire)
1.  Remove the external ground connector’s 
screw, and connect the ground wire 
(green or unwrapped) of the power cable 
to the screw.
CAUTION
•  To connect the ground wire to the 
neutral position without through 
contact A (cabinet ground), contact 
a technician. This is not user 
serviceable.
•  Ring-type terminals are remended. If 
using strap terminals, make sure they 
are tightened.
2.  Loosen or remove the screws from the 
center terminal block.
3.  Connect the neutral wire (white or 
center wire) and ground wire (white) to 
the center screw of the terminal block. 
Tighten the screw.
4.  Connect the other wires to the outer 
terminal block screws. Tighten the 
screws.
5.  Tighten the strain relief screws.
6.  Insert the tab of the terminal block cover 
into the rear slot of the dryer. Secure the 
cover with a hold-down screw.
WARNING
•  All U.S. models are designed for a 3-wire system connection. The dryer frame is 
grounded to the neutral conductor at the terminal block. A 4-wire system connection 
is required for new or remodeled construction, mobile homes, or if local codes do not 
permit grounding through neutral. If you use the 4-wire system, you cannot ground the 
dryer frame to the neutral conductor at the terminal block.
•  Remove the terminal block cover plate. Insert the power cord with a UL-listed strain 
relief through the hole provided in the cabinet near the terminal block.
•  A strain relief must be used. Do not loosen the nuts already installed on the terminal 
block. Be sure they are tight. Use a 
3
/
8
” (1 cm) deep well socket.
DV7450M-03170Z-00_EN.indd   21