Intel® Server System SR1695GPRX TPS
Cooling Sub-System
Revision 1.5
29
Intel order number: G11332-006
Figure 14. Processor Heatsink Overview
Note: The passive heatsink is Intel
®
standard thermal solution for 1U/2U rack chassis.
4.2
System cooling Fans
The Intel
®
Server System SR1695GPRX cooling subsystem consists of two 97 x 94 x 33 blower
fans and one 40 x 40 x 15 rotor fan, and CPU air duct. These components provide the
necessary cooling and airflow to the system. A fan on the processor heatsink is not needed.
necessary cooling and airflow to the system. A fan on the processor heatsink is not needed.
To maintain the necessary airflow within the system, the air duct and the top cover must be
properly installed.
properly installed.
Note: The Intel
®
Server Systems SR1695GPRX does not support redundant cooling. If a fan
blower fails, the system should be powered down as soon as possible to replace the failed fan
blower. The system fans are not hot-swappable.
blower. The system fans are not hot-swappable.
Each fan within the module is capable of supporting multiple speeds. Fan speed changes
automatically when internal ambient temperature of the system or processor temperature
changes. The fan speed control algorithm is programmed into the server board’s BIOS.
automatically when internal ambient temperature of the system or processor temperature
changes. The fan speed control algorithm is programmed into the server board’s BIOS.