Intel SR1695GPRX1AC 用户手册

下载
页码 83
Intel® Server System SR1695GPRX TPS 
Cooling Sub-System 
Revision 1.5 
 
 
29 
Intel order number: G11332-006 
 
 
Figure 14. Processor Heatsink Overview 
Note: The passive heatsink is Intel
®
 standard thermal solution for 1U/2U rack chassis. 
 
4.2 
System cooling Fans 
The Intel
®
 Server System SR1695GPRX cooling subsystem consists of two 97 x 94 x 33 blower 
fans and one 40 x 40 x 15 rotor fan, and CPU air duct. These components provide the 
necessary cooling and airflow to the system. A fan on the processor heatsink is not needed.  
To maintain the necessary airflow within the system, the air duct and the top cover must be 
properly installed. 
Note: The Intel
®
 Server Systems SR1695GPRX does not support redundant cooling. If a fan 
blower fails, the system should be powered down as soon as possible to replace the failed fan 
blower. The system fans are not hot-swappable. 
Each fan within the module is capable of supporting multiple speeds. Fan speed changes 
automatically when internal ambient temperature of the system or processor temperature 
changes. The fan speed control algorithm is programmed into the server board’s BIOS.