Samsung SDM-160N 用户手册

下载
页码 41
Digital Multiplexer 
7-1
Chapter 7. Occurrence and handling of alarm, loss, motion
1.Alarm occurrence conditions
The following events occur if alarm occurs since the sensor is connected to the alarm input terminal
on the backside: 
1) Warning sounds (if buzzer turns “ON”).
2) Alarm information (date and time when alarm occurs) is recorded on the alarm list. 
3) “RESET” LED blinks.
4) The alarm output (HOT, COLD) signal is active for the alarm hold time. 
5) The record times of the channel that alarm occurs increase.
6) Display character of “ALARM” or “A” appears (if the alarm information turns “ON”). 
7) Alarm continues for the alarm hold time that is set in the program mode. 
Alarm holds time: Time performing alarm operation after recognizing alarm.
2.Alarm release
The alarm status is released if pressing the “RESET” button when alarm occurs or the alarm holds time set-
ting passes.
3.Alarm record
Perform the alarm weight value record in the chapter 6. 
4.Alarm signal standard
You can view record output when alarm occurs during record.
For example, if record status have the following conditions:
• 
Currently perform record in the TLV mode on the time lapse VCR.
• 
Set the “REC TYPE” to “NOR” in the “5. ALARM SET” of the “program mode”.
The record output until release after the alarm occurs is as follows:
VCR TRIG
Record output 
operation 
ALARM/MOTION OUT
Output
ALARM RESET
Output
TLV operation
NOR operation 
TLV 
TRIG  override
Alarm occurrence                    Alarm reset
More than 150ms