    B. Red caution light is solid or 
Salt level is very high. The generator could
Drain part of the water and refill the pool.
        output lights 1-7 go up
completely turn off and no longer produce
It is also recommended to periodically test
and down quickly.
chlorine until the situation is rectified.
the salt level by a professional. If above
        
5500 ppm, check with your dealer about drain-
 
ing the pool water and refilling with fresh water.
1. Make sure your filtration system is working 
properly (i.e. clean filter and/or skimmer).
2. Make sure circulation time is adequate – 
 10.  Cloudy Water
May be due to chemical imbalance
increase pump time if not.
or low water flow.
3. Make sure total alkalinity is within 60-120 
ppm. Adjust with acid if needed.
4. Shock the water to eliminate build up of any 
organic matter.
5. Make sure pool has a free chlorine reading 
of 0.5 to 1.0 ppm.
6. Check with your dealer for more information.
Control knob set too low.
Turn control knob up (clockwise).
7.  Output Level Lights 
     Not Responding, but
     Power Light is On
Improper salt level.The system automatically
Check salt level using a test kit or your local
shuts down the output level when the salt 
pool professional. See Salt Level Low or Salt
level is extremely low or extremely high.
Level High instructions above. Adjust accordingly.
Wires from control panel to cell are loose
Check the connection. Wires should be slid
or the screws to the connectors are
over the pegs on the cell and the screws
not tight.
tightened firmly. See cell-wiring diagram page 11.
8.  Scale Buildup Inside Cell
Standard occurrence that needs to be
Clean cell as instructed on page 11.
cleaned approximately twice per year.
Chemical imbalance.
Balance chemicals. (Focus mostly on the 
“Saturation Index” on page 16.)
9.  White Flakes In  Water
Normal occurrence when cell cleans itself.
Keeping the water well balanced reduces this.
(Focus mostly on the “Saturation 
Index” on page 16.)
6.  Salt Level High
This does no harm to the generator. Slowly 
   A. Red caution light is flashing.
Salt level is on the high side.
turn down the control knob to return to desired
   
output setting. It is also recommended to 
periodically test the salt level by a professional.
 
Check the cell to ensure the plates are in good
condition and not coated with calcium buildup.
Dirty cell.
Cleaning the cell is recommended if it is 
calcified or if the readout seems questionable.
See “Cell Cleaning” page 11.
5.   Output Light #7 is
     not lit when turning 
Loose connection with the cell’s
Ensure the connectors are pushed completely
     control knob all the
connection pegs.
over the pegs and tighten connections with a
     way up.
screwdriver. See cell-wiring diagram page 11.
Add salt into the pool.  See “Adding Salt” on
 
page 6. It is also recommended to periodically
Not enough salt due to heavy rain, splash out,
test the salt level by a professional and adjust
initial miscalculation, etc.
according to the “Salinity Demand Table” on 
page 6.
Worn cell. 
If none of the above resolutions worked, the 
cell may be worn out and must be replaced.
14
PROBLEM
POSSIBLE CAUSES
WHAT TO DO