 VoIP Commands
Page 5-47
Command Usage
Specify voice port transmit clock source.
Syntax Options
voice port transmit clock source
voice port <
slot/port 
> transmit clock source {loop timing | local timing}
Definitions: 
slot
Specifies slot number of voice switching daughtercard installed in switching module,
(e.g., 
2
).
port
Specifies physical port number on voice daughtercard, (e.g., 
1
).
loop timing
Indicates that the recovered receive clock is being used as the transmit clock.
local timing
Indicates that a local clock source is being used as the transmit clock.
Default:
The default setting is 
local timing
.
Command Examples:
voice port 2/1 transmit clock source local timing