Alcatel-Lucent omniacces-voip gateway 用户手册

下载
页码 430
 VoIP Commands
Page 5-125
Command Usage
Specify Foreign Exchange Office Loop Start (FXO LS) debounce for battery reversal detector.
Syntax Options
Remarks
The 
voice signaling protocol
 command must be set to the corresponding protocol type before 
any commands for E&M (Wink Start, Immediate Start, and Delay Start Signaling), and FXS/
FXO (Loop and Ground Start) commands will take effect.
voice signaling fxo ls battery reversal debounce
voice signaling channel <
slot/port/startChannel-endChannel
 > fxo ls battery reversal debounce 
<
value 
>
Definitions:
slot
Specifies chassis slot number where VSM is installed, (e.g., 
2
).
port
Specifies physical port number on voice daughtercard, (e.g., 
1
).
startChannel
The first number in the range of voice channels (e.g., 
1
).
endChannel
The last number in the range of voice channels (e.g., 
30
). 
 Syntax Note 
Be sure to separate the start and end range numbers with a 
hyphen (e.g., 
1-30
).
value
Specifies the time to use as a debouncer (delay interval) for debouncing the battery rever-
sal detector, in milliseconds from 0 to 60,000, (e.g., 
20
).
 Syntax Note 
Do not use commas when entering the fxo ls debounce value 
for the battery reversal detector (for example, 
10,000
 will return 
a syntax error message).
Default:
The default value is 
20
 milliseconds.
Command Examples:
voice signaling channel 2/1/1-12 fxo ls battery reversal debounce 20
voice signaling channel 2/2/13-24 fxo ls battery reversal debounce 30000