Alcatel-Lucent omniacces-voip gateway 用户手册

下载
页码 430
 VoIP Commands
Page 5-145
Command Usage
Specify Foreign Exchange Office (FXO) Ground Start (GS) debounce interval for loop current 
detector.
Syntax Options
Remarks
The 
voice signaling protocol
 command must be set to the corresponding protocol type before 
any commands for E&M (Wink Start, Immediate Start, and Delay Start Signaling), and FXS/
FXO (Loop and Ground Start) commands will take effect.
voice signaling fxo gs loop current debounce
voice signaling channel <
slot/port/startChannel-endChannel
 > fxo gs loop current debounce 
<
value 
>
Definitions:
slot
Specifies chassis slot number where VSM is installed, (e.g., 
2
).
port
Specifies physical port number on voice daughtercard, (e.g., 
1
).
startChannel
The first number in the range of voice channels (e.g., 
1
).
endChannel
The last number in the range of voice channels (e.g., 
30
). 
 Syntax Note 
Be sure to separate the start and end range numbers with a 
hyphen (e.g., 
1-30
).
value
Specifies the debounce (delay interval) for debouncing the loop current detector, in milli-
seconds from 1 to 1,000, (e.g., 
20
).
 Syntax Note 
Do not use commas when entering the fxs gs debounce interval 
value for loop current detection (for example, 
1,000
 will return 
a syntax error message).
Default:
The default value is 
20
 milliseconds.
Command Examples:
voice signaling channel 2/1/1-12 fxo gs loop current debounce 20
voice signaling channel 2/2/13-24 fxo gs loop current debounce 500
voice signaling channel 2/3/1-30 fxo gs loop current debounce 1000