Interfaces
4-37
Printer Configuration
Baud Rate
Sets the rate data is received (bits per second) from the host over the 
serial interface. 
Data Bits
Sets the number of data bits transmitted per character. 
Default Job Priority
Allows you to specify which jobs are printed first, according to the 
interface through which they are received, when jobs are received 
simultaneously. In other words, you can give jobs received via the 
Menu
Administration/Communications/Serial/Baud Rate
Choices
300, 600, 1200, 2400, 4800, 9600, 19200, 38400
Default
9600
Notes
Set this option to match the baud rate used by the host. Baud 
rates of 19200 and 38400 require RTS/CTS hardware flow 
control (Administration/Communications/Serial/Hdwe Flow Ctl 
menu). These rates do not support XON/XOFF software flow 
control (Administration/Communications/Serial /Rcv Sw Flow 
Ctl menu).
When selecting a baud rate of 2400 or below, increase the 
Administration/Communications/Timeouts/Emul Timeout 
value as follows:
Baud Rate
Emulation Timeout (seconds)
2400
10*
1200
20
600
40
300
80
*A baud rate of 2400 works with a 5-second emulation timeout 
value, but there is no margin for delays between characters.