b.  Secure the server by tightening the thumbscrews. 
6.  Reconnect the peripheral cables and power cords. 
 
Removing the access panel 
  WARNING:  To reduce the risk of personal injury from hot 
surfaces, allow the drives and the internal system components to 
cool before touching them.
 
  CAUTION:  Do not operate the server for long periods without 
the access panel. Operating the server without the access panel results 
in improper airflow and improper cooling that can lead to thermal 
damage. 
1.  Power down the server if the standard cable management solution is installed 
NOTE:  If the optional cable management arm is installed, you can 
extend the server and perform hot-plug installation or maintenance 
procedures without powering down the server. 
2.  Extend the server from the rack, if applicable ("Extending the server from the 
3.  Lift up on the hood latch handle and remove the access panel. 
 
Installing the access panel 
1.  Place the access panel on top of the server with the hood latch open. Allow 
the panel to extend past the rear of the server approximately 8 mm (0.2 in). 
2.  Engage the anchoring pin with the corresponding hole in the latch. 
3.  Push down on the hood latch. The access panel slides to a closed position.