Sony HDW-F500 用户手册

下载
页码 176
Appendix
A-63
Appendix
Items Related to the Pull Down Control (A01~)
The values enclosed in a box are the factory settings.
Item number
Settable range
Function
Item
A01
PD TIME CODE
DISPLAY
[off]
on
Sets whether or not to display the pull down time code on
the time code display area.
off: Does not display the pull down time code.
on: Displays the pull down time code.
A02
PD PRESET
FRAME MODE
[24 FRAME MODE]
30 FRAME MODE
Selects the time code to be preset.  The A frame of the
pulldown sequence can be preset.
24 FRAME MODE: The 24 frames time code is preset.
30 FRAME MODE: The 30 frames time code is preset.
A03
PD
SUPERIMPOSED
CHARACTER
[off]
on
Specifies whether or not to superimpose time data and
operating status information on the signal output from the
PULL DOWN OUT connector.
off: No information is superimposed.
on: Information is superimposed.
A04
PD DF/NDF
SELECT
[drop frame]
non-drop frame
auto
Selects the running mode for the pull down time code to be
preset.
drop frame: Drop frame mode
non-drop frame: Non-drop frame mode
auto: The unit switches the running mode (DF/NDF)
automatically according to the frame frequency of the
unit.  When the frame frequency is 23.976 Hz, the unit
switches to the drop frame mode and switches to the
non-drop frame mode when it is 24 Hz.