Nokia 6021 服务手册
![Nokia](https://files.manualsbrain.com/attachments/dce7461e47de2eca5f7d09be31ff1fc55db75997/common/fit/150/50/3540f9922a492527aa17737eb6cc8428f11e9c5169db0829a90bcdf9088f/brand_logo.jpeg)
RM-94
Nokia Customer Care
6(b) - RF Troubleshooting
10
COMPANY CONFIDENTIAL
Issue 1 04/2005
Copyright © 2005 Nokia. All Rights Reserved.
Select
Scan Product
Ctrl-R
Wait until the phone information is shown in the lower right corner of the screen.
Set <operating mode> to <local mode>.
Select
Testing
T
RF Controls
F
Select
Band
GSM 900 or GSM1800 or GSM1900
Active unit
RX
Operation mode
Continuous
RX/TX Channel
37 or 700 or 661
Please refer to the fault finding chart and Appendix for proper levels at different test points.
Measuring analogue RX I/Q signals using oscilloscope
Measuring with an oscilloscope RX I and RX Q signals on the test points <RXI> respectively
<RXQ> is recommended only if the RSSI reading does not provide enough information. Input
level = -60dBm.
<RXQ> is recommended only if the RSSI reading does not provide enough information. Input
level = -60dBm.
Start Phoenix Service Software and open FBUS connection.
Select
Scan Product
Ctrl-R
Wait until phone information is shown in the lower right corner of the screen.
Set operating mode to <local mode>.
Select
Testing
T
RF Controls
F
Wait until the RF Controls window pops up.
Select
Band
GSM 900 or GSM1800 or GSM1900
Active unit
RX
Operation mode
Continuous
RX/TX Channel
37 or 700 or 661
AGC
10
The following picture should be displayed on an oscilloscope's screen if the receiver is working
properly:
properly: