Nokia n-gageqd 服务手册
RH-29
Company Confidential
7 - System Module
Nokia Customer Care
Page 18
Copyright ©
2004 Nokia Corporation
Issue 1 05/2004
Company Confidential
Extreme voltages
Lithium-Ion battery BL6-C (1 cell):
Nominal voltage is 3.7V
Lower extreme voltage is 2.8V (cut off voltage)
Higher extreme voltage is 4.2V (charging high limit voltage)
Temperature conditions
Specifications are met within range of –10C to +55C ambient temperature. Reduced
operation between [-30] and [+60]. Storage temperature range is of –40C to +85C.
operation between [-30] and [+60]. Storage temperature range is of –40C to +85C.
Humidity and water resistance
Relative humidity range is 5 … 95%. Condensed or dripping water may cause intermit-
tent malfunctions. Protection against dripping water have to be implemented in (enclo-
sure) mechanics. Continuous dampness will cause permanent damage to the module.
tent malfunctions. Protection against dripping water have to be implemented in (enclo-
sure) mechanics. Continuous dampness will cause permanent damage to the module.