Nokia n-gageqd 服务手册

下载
页码 60
RH-29
Company Confidential
3 - Service Software
Nokia Customer Care
Page 24
         Copyright ©
 2004 Nokia Corporation
Issue 1  05/2004
Company Confidential
Energy Management Calibration
Connections
RH-29 phone must be connected to JBV-1 (Docking station) with DA-17 (Docking station 
adapter).
Connect CA-5S (DC-DC cable) from JBV-1 into to phone charger con-
nector before powering up JBV-1.
Power up JBV-1 from external power supply: 11-16 V DC. (Do not take 
power from FPS-8 in calibration mode).
Phoenix setup
Start Phoenix.
Select FBUS connection.
Choose Main -> Choose product… 
Choose Maintenance -> Tuning -> Energy Management Calibration 
component.
Calibration
1) Mark all channels (ADC, Battery Size…except Battery temperature).
Figure 4: Energy Management Calibration screen
2) Press Calibrate button.