Company Confidential
Energy Management Calibration
Connections
RH-29 phone must be connected to JBV-1 (Docking station) with DA-17 (Docking station
adapter).
adapter).
•
Connect CA-5S (DC-DC cable) from JBV-1 into to phone charger con-
nector before powering up JBV-1.
nector before powering up JBV-1.
•
Power up JBV-1 from external power supply: 11-16 V DC. (Do not take
power from FPS-8 in calibration mode).
power from FPS-8 in calibration mode).
Phoenix setup
•
Start Phoenix.
•
Select FBUS connection.
•
Choose Main -> Choose product…
•
Choose Maintenance -> Tuning -> Energy Management Calibration
component.
component.
Calibration
1) Mark all channels (ADC, Battery Size…except Battery temperature).
Figure 4: Energy Management Calibration screen
2) Press Calibrate button.