The spectrum analyzer shows a plot like this:
6
To adjust the +67kHz signal to a minimum level (Marker 3), use the variables 
“Amplitude difference” and “Phase difference”.
After tuning to the minimum, the level difference between the peak levels at 
marker 1 and 3 must exceed 40 dB.
Tuning is possible by using arrow keys on the keyboard. Pushing the sliders by 
using the mouse is less sensitive.