Panasonic cu-e18gfe-2 用户手册

下载
页码 42
7
1. Cooling capacities are based on indoor temperature of 27
°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35
°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6
°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
Note
• Specifications are subject to change without notice for further improvement.
Fan
Type
Turbo Fan
Propeller Fan
Material
ASG
PP
Motor Type
Transistor (8-pole)
Induction (6-pole)
Input Power
W
71.3 - 80.7
Output Power
W
48
30
Fan Speed
QLo (Cool/Heat)
rpm
 370 / 360
Lo (Cool/Heat)
rpm
 430 / 410
Me (Cool/Heat)
rpm
530 / 530
Hi (Cool/Heat)
rpm
640 / 650
815 - 845 / -
SHi (Cool/Heat)
rpm
680 / 690
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2 x 22 x 19
2 x 24 x 17
Size (W x H x L)
mm
510 x 396 x 24
36.4 x 504 x 713
684
Air Filter
Material
PET
Type
Honeycomb
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
220 - 240
Hz
50
Input Power
W
Cooling; 965 (185 ~ 1140)
Heating; 1320 (175 ~ 1770)
Starting Current
A
6.25
Running Current
A
Cooling; 4.60 - 4.25
Heating; 6.25 - 5.80
Maximum current
A
8.70
Power Factor
%
Cooling; 95 - 95
Heating; 96 - 95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
Length
m
Thermostat
Electronic Control
Protection Device
Electronic Control
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT