I N S TA L L AT I O N   I N S T RU C T I O N S
I N S TA L L AT I O N   I N S T RU C T I O N S
Electrical Requirements for Gas Models Only
•  Do not, under any circumstances, cut or 
remove the third (ground) prong from the 
power cord. 
Failure to follow this warning can 
result in fi re, explosion, or death.
•  For personal safety, this dryer must be 
properly grounded. Failure to follow this warning 
can result in fi re, explosion, or death.
•  The power cord of this dryer is equipped with 
a 3-prong (grounding) plug which mates with 
a standard 3-prong (grounding) wall outlet 
to minimize the possibility of electric shock 
hazard from this appliance.
 Failure to follow 
this warning can result in fi re, explosion, 
or death.
•  This dryer must be plugged into a 
120-VAC, 60-Hz. grounded outlet protected by 
a 15-ampere fuse or circuit breaker.
 Failure to 
follow this warning can result in fi re, explosion, or 
death.
•  Where a standard 2-prong wall outlet is  
encountered, it is your personal responsibility 
and obligation to have it replaced with a 
properly grounded 3-prong wall outlet. 
Failure 
to follow this warning can result in fi re, explosion, 
or death.
16
CONNECTING GAS DRYERS
• Gas supply requirements: 
As shipped from the factory, this dryer 
is confi gured for use with natural gas. 
It can be converted for use with LP (Liquefi ed 
Propane) gas. Gas pressure 
must not exceed 13 in. water column.
• A qualifi ed service or gas company technician 
must connect the dryer to the gas service. 
Failure to do so can result in fi re, explosion, or 
death.
• Isolate the dryer from the gas supply system 
by closing its individual manual shutoff valve 
during any pressure testing of the gas supply. 
Failure to do so can result in fi re, explosion, or 
death.
• Supply line requirements: 
Your laundry room must have a rigid gas 
supply line to your dryer. In the United States, 
an individual manual shutoff valve MUST be 
installed within at least 6 ft. (1.8 m) of the 
dryer, in accordance with the National Fuel 
Gas Code ANSI Z223.1. A 1/8-in. NPT pipe 
plug must be installed.
 Failure to do so can 
result in fi re, explosion, or death.
• If using a rigid pipe, the rigid pipe should be 
1/2-in. IPS. If acceptable under local codes 
and ordinances and when acceptable to your 
gas supplier, 3/8-in. approved tubing may be 
used where lengths are less than 20 ft. (6.1 
m). Larger tubing should be used for lengths 
in excess of 20 ft. (6.1 m).
 Failure to do so can 
result in fi re, explosion, or death.
• Connect the dryer to the type of gas shown 
on the nameplate. Failure to do so can result in 
fi re, explosion, or death.
• To prevent contamination of the gas valve, 
purge the gas supply of air and sediment 
before connecting the gas supply to the dryer. 
Before tightening the connection between the 
gas supply and the dryer, purge remaining air 
until the odor of gas is detected.
 Failure to do 
so can result in fi re, explosion, or death.
• DO NOT use an open fl ame to inspect for 
gas leaks. Use a noncorrosive leak-detection 
fl uid. 
Failure to do so can result in fi re, explosion, 
or death. 
• Use only a new AGA- or CSA-certifi ed gas 
supply line with fl exible stainless steel 
connectors.
 Failure to do so can result in fi re, 
explosion, or death.
• Securely tighten all gas connections. Failure to 
do so can result in fi re, explosion, or death.
• Use Tefl on
®
 tape or a pipe-joint compound 
that is insoluble in Liquefi ed Petroleum (LP) 
gas on all pipe threads.
 Failure to do so can 
result in fi re, explosion, or death.
• DO NOT attempt any disassembly of the 
dryer; any disassembly requires the attention 
and tools of an authorized and qualifi ed 
service person or company.
 Failure to do so 
can result in fi re, explosion, or death.
wWARNING: 
To reduce the risk of fire, electric shock, or injury to persons when using this 
appliance, follow basic precautions, including the following: