9. 
Physical and Chemical Properties of Ink Formulation 
 
Appearance: 
Moist Magenta Powder 
Odor: 
Slight 
pH: Organically 
neutral 
Boiling point: 
Not applicable 
Freezing point: 
Not applicable 
Softening point: 
120 –130 
°C  
Flash point: 
> 230 
°F / 110 °C (CC) 
Autoflammability: 
Over 300 
°C 
Explosive properties: 
None 
Oxidizing properties: None 
Vapor density: 
Not applicable  
Relative density: 
1.12 at 68 
°F / 20 °C 
Solubility in water: Negligible 
Solubility in fat: 
No data available 
Partition coefficient: 
No data available 
Viscosity: 
Less than 5 mPa-s 
 
10.  Stability and Reactivity 
 
Stability: Stable 
Hazardous polymerization: 
Will not occur 
Hazardous decomposition products: None 
Incompatible materials: 
Oxidizers and explosives 
 
11.  Toxicology and Health Hazards 
 
Routes Of Overexposure:  Eye, skin, inhalation, and oral 
 
Acute Health Hazards: 
•  Overexposure of eye surface to toner may be mildly irritating
 
• 
Overexposure of skin to toner contact may cause irritation and in some people swelling and redness
 
 
•  Intentional or accidental inhalation overexposure to toner may result in respiratory tract irritation 
•  Intentional or accidental oral ingestion may cause an upset stomach 
 
Chronic Health Hazards:       
Use of this product, as intended, does not result in inhalation of fugitive excessive dust.  In an 
                                                    inhalation study with rats chronically exposed to a typical developer, a mild to moderate degree 
                                                    of lung fibrosis was observed in approximately 90% of rats in the high concentration exposure group 
                                                    (16mg/cubic meter), and a minimal to mid degree of fibrosis was noted in approximately 20% of the 
                                                    animal in the middle exposure group (4mg/cubic meter).  But no pulmonary change was reported in 
                                                    the lowest exposure group (1mg/cubic meter), the most relevant level to potential human  
                                                    exposure.    
 
 
Carcinogenicity:             
With excessive exposure, carbon black has been listed as a possible human carcinogen. 
                                            However, as engineered within this toner cartridge, emissions to air of carbon black 
                                            during normal printing use have not been found.  IARC, the International Agency for 
                                            Research on Cancer, has found printing toners to be not classifiable as human 
                                            carcinogens.       
 
Toxicity Data: 
Oral LD50 
Dermal LD50 
Inhalant LC50 
OSHA Regulated? 
 
> 5000mg/kg(Rats) 
> 5000mg/kg(Rats) 
4.1mg/L/4hr(Rats) 
Not Established