MAINTENANCE AND CARE
- ALWAYS KEEP THE UNIT CLEAN -
AIR FILTER
Clean before using the unit.
- Close choke. Disengage latch and remove air
cleaner cover.
- Remove air filters (felt and sponge).
- Air filter (flet): Brush off dust lightly or clean with
compressed air.
- Air filter (sponge): Brush off dust lightly or wash
it in  a non-inflammable solvent if necessary.
- Soak air filter (sponge) into 2 stroke oil and
squeeze it firmly not to allow remaining oil to
trickle.
- Install the air filter (sponge) into air cleaner cover.
- Install the air filter (felt) into cleaner case.
- Install assembled air clearner cover on cleaner
case with air filter (felt) and engaged latch.
FUEL STRAINER
Check periodically.
- Do not allow dust to enter into fuel tank.
- Clogged strainer will cause difficulty in starting
engine or abnormalities in engine performances.
- Pick up fuel strainer through fuel inlet port with a
piece of steel wire or the like.
- When strainer is dirty, wash it in suitable
cleaning fluid or replace it.
CYLINDER FINS
Check periodically.
Clogged fins will result in poor engine cooling.
Remove dirt and dust from between fins to let
cooling air pass easily.
Cylinder fins
MUFFLER AND EXHAUST PORT (SAM)
Clean as necessary.
Carbon deposits in cylinder exhaust port and
muffler will reduce engine output.
- Muffler can be removed by taking off muffler
cover.
- Remove spark arrestor screen from muffler.
- Clean carbon deposits from screen and muffler
components.
- Be careful not to scratch cylinder or piston when
cleaning cylinder exhaust port.
Use non-ferrous plastic or wood.
- Replace spark arrestor screen if it is cracked,
plugged or has holes burned through.
- Inspect gaskets, replace if damaged.
- Assemble components in reverse order.
Latch
Cleaner case
Air filter (felt)
Air cleaner cover
Air filter (sponge)
Fuel strainer
Muffler cover
Lid
Spark arrestor screen
Air intake