Initial Installation
QUALIFIED INSTALLERS ONLY
I
NSTALLATION
 
OF
 A
PPLIANCE
:
Sealant
Female
Locking
Lugs
Male
Locking
Lugs
Figure 26: Twist-Lock 
Connection.
- PO512-54 DMS). Refer to M
AINTENANCE
 A
ND
 S
ERVICE
 - F
UEL
 C
ONVERSION
3. Set the appliance in the desired location. Check to determine if wall studs are in the way when the 
venting system is attached. If this is the case, you may want to adjust the location of the appliance.
4. Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the desired 
combination of black pipe and elbows to the appliance adapter with pipe seams oriented towards the 
wall or floor, as much out of view as possible.
17
Figure 25: Converting Top Vented into Rear Vented.
1. This unit has been shipped as a top-vented 
freestanding unit and must be converted to a 
rear vented unit before installed. 
a. Carefully remove the trivet and the stovetop. 
Place on a soft surface as not to damage the 
finish.
b. Remove the four (4) 1⁄4” screws that hold the 
flue collar elbow to the unit body. 
c. Carefully remove the elbow being sure not to 
damage the gasket that is glued to the flue 
collar  elbow,  it  seals  the  flue  to  the  firebox 
(see Figure 25).
d. Turn the elbow 180° to the rear vent position 
and  re-fasten  with  the  screws  removed  in 
step b.
2. This  unit  has  been  shipped  with  a  Cara 
orifice installed and it must be replaced with 
a Cara DR orifice  (NG - PO512-42 DMS or LP 
  Place a bead of Mil-Pac on the outer edge of the inner exhaust pipe 
(non-flared end). Place a bead of high temperature silicone on the male 
edge of the outer pipe. Push the pipe sections completely together, then 
twist-lock one section clockwise approximately 1⁄4 turn, until the two (2) 
sections are fully locked. The female locking lugs will not be visible from 
the outside, on black pipe. They may be located by examining the inside 
of the female ends as shown in Figure 26.
Notes: 
(a) Twist-lock procedure: four (4) indentations, located on the female end 
of the pipes and fittings, are designed to slide straight onto the male ends 
of adjacent pipes and fittings, by orienting the four (4) pipe indentations so 
they match and slide into the four (4) entry slots on the male end.
(b)  Pipe  minimum  clearances  to  combustibles  must  be  maintained;  2” 
(51mm) at top, 11⁄2” (38mm) at sides, 11⁄2” (38mm) at bottom.
3.
 With the pipe attached to the stove in the correct location, mark the wall for a 10” (25.4cm) x 10” 
(25.4 cm) square hole (refer to Figure 27). The center of the square hole should match the center line 
of the horizontal pipe. Cut and frame the 10” (25.4cm) x 10” (25.4cm) hole in the exterior wall where 
the vent will be terminated. Refer to Figure 24 and Table 7. If the wall being penetrated is constructed 
of non-combustible material i.e. masonry or concrete, a 7” (17.8cm) hole is acceptable.
4. Position the horizontal vent termination in the center of the 10” (25.4cm) x 10” (25.4cm) hole, and 
attach to the exterior wall with the four (4) screws provided. Before attaching the vent termination to 
the exterior wall, run a bead of non-hardening mastic around the edges, so as to make a seal between