If the rocks are positioned incorrectly, the flames can be “pinched” and will not burn correctly. If the rocks 
are broken due to handling or shipping, replace the rocks with new ones. Using the pictures provided, 
carefully set the rocks in place.
Secondary Installation
Important  note:  When  the  unit  is 
turned  on  for  the  first  time,  it  should 
be  turned  onto  high  without  the  fan 
on for the first four (4) hours. This will 
cure  the  paint,  logs,  gasket  material 
and  the  other  products  used  in  the 
manufacturing  process.  It  is  advisable 
to open a window or door, as the unit 
will  start  to  smoke  and  can  irritate 
some  people.  After  the  unit  has  gone 
through the first burn turn the unit off 
including the pilot, let the unit get cold 
then remove the glass door and clean it 
with a good gas fireplace glass cleaner, 
available at your local ENVIRO dealer.
See M
AINTENANCE
 A
ND
 S
ERVICE
 on how to 
remove door to clean glass.
Figure 43: Cara DR with a Good Flame.
CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED.
NOTE:  The  rocks  are  fragile,  particularly 
after  usage.  Please  handle  with  due  care 
during servicing.
1. Carefully  remove  rocks  from  box  and  check 
there  is  no  damage.  It  is  very  important  to 
install  all  rocks  in  their  proper  position  to 
ensure safe, optimum operating conditions.
2. Place the rock cluster onto the burner. There 
are  two  (2)  holes  at  the  back  corners  of 
the  burner  and  two  (2)  aligning  pins  on  the 
bottom of the rock cluster (refer to Figures 44 
& 45).
Figure 44: Installation of Rock Cluster.