Exhaust Requirements
35
70269701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 9
NOTE: Do not install wire mesh or screen in
exhaust duct opening to avoid lint build-up or
impacting proper discharge of air from tumblers.
exhaust duct opening to avoid lint build-up or
impacting proper discharge of air from tumblers.
NOTE: Where exhaust duct pierces a combustible
wall or ceiling, the opening must be sized per local
codes.
wall or ceiling, the opening must be sized per local
codes.
NOTE: Inside of duct must be smooth. Do not use
sheet metal screws to join sections.
sheet metal screws to join sections.
Consult your local building code for regulations which
may also apply.
may also apply.
TMB2103N
1
Removable strip of panel in framing wall to permit removal of tumbler from framing wall
2
Partition or bulkhead
3
Minimum distance between exhaust opening and roof, ground or other obstruction: 36 in. (914 mm)
4
2 in. (51 mm) minimum clearance on both sides of duct
5
Exhaust airflow – maximum length of duct: 14 ft. (4.3 m)
TMB2103N