Siemens siemens network router mc35 用户手册

下载
页码 65
Remote-SAT User's Guide
MC35_SAT_01_v02.00
Page 52 of 65
11.01.2002
1.5.2.11 
AT^SSTR  Remote-SAT Response – Get Input (35)
Write command
AT^SSTR=35,
<status>, ,
<inputString>
The TA sends a response that can indicate the user's intentions and include the
input string.
Response
OK
Parameters
<cmdType> 35 – Proactive command ID, see Table 1
<status>
Unsigned Integer, range 0-255
0
Command performed successfully
16
Proactive SIM session terminated by user
17
Backward move in the proactive SIM session requested
by the user
18
No response from user
19
Help information required by the user
32
TA currently unable to process command
132
TA currently unable to process command because
screen is busy.
<inputString>
User response entered as a string, length depends on values
of <responseMin> and <responseMax> returned by the
related AT^SSTGI command.
Coding of any input character is related to the selected alphabet:
 
Input of a character in case of ANSI character set requests one byte , e.g.
“Y”.
 
Input of a characters in UCS2 alphabet requests a 4 byte string, e.g. “0059”
is coding the same character “Y”.
 
Coding of an empty string is done as “\1b” in every alphabet.
Reference
Siemens
Note
The alphabet – and therefore the set of allowed characters - is specified by the
ME in the response to the related AT^SSTGI. However, do not mix up this
alphabet with the one selected for the alphabet format on the transmission line
on SAT activation, i.e. second parameter of AT^SSTA).