RDVDSN Series Direct Vent Gas Fireplace
20007894
IMPORTANT: Always check for gas leaks with a 
soap and water solution. Do not use open flame for 
leak testing.
Air Shutter Settings
 
 
Opening
 
Model 
“A” 
 
33RDVDSN 
1/32”   (1.0 mm)
 
33RDVDSP 
3/8”   (9.5 mm)
 
36RDVDSN 
1/32”   (1.0 mm)
 
36RDVDSP 
3/8”   (9.5 mm)
 
39RDVDSN 
1/32”   (1.0 mm)
 
39RDVDSP 
3/8”   (9.5 mm)
NOTE: These are minimum settings. Air shutter open-
ings may be  increased to prevent flame sooting.
T203
Air shutter
12/12/03  djt
T203
Opening 
“A”
Fig. 51  Air shutter opening.
Conversion Kits
 
 
Change Natural  Change Propane 
 
Model 
to Propane 
to Natural
  33RDVDSN 
20007864* 
--
  33RDVDSP 
-- 
  36RDVDSN 
20007891* 
--
  36RDVDSP 
-- 
  39RDVDSN 
20007903* 
--
  39RDVDSP 
-- 
* Included with fireplace.
Normal and High 
Direct Vent Units - Inputs - Orifice Size - Altitude
 
 
BTU/Hr 
Manifold Pressure 
Orifice 0 - 2000ft. Altitude in USA
 
Model 
Max. Input 
@ Max. 
Orifice 0-4500ft Altitude in Canada
 
33RDVDSN 
18,000 
3.5”w.c. 
#47 DMS
 
33RDVDSP 
18,000 
10.0” w.c. 
 #56 DMS
 
36RDVDSN 
20,000 
3.5” w.c. 
#45 DMS
 
36RDVDSP 
20,000 
10.0” w.c. 
 #55 DMS
 
39RDVDSN 
22,000 
3.5” w.c. 
#43 DMS
 
39RDVDSP 
22,000 
10.0” w.c. 
 #54 DMS