temco-tool 39rdvdsn 用户手册
31
RDVDSN Series Direct Vent Gas Fireplace
20007894
IMPORTANT: Always check for gas leaks with a
soap and water solution. Do not use open flame for
leak testing.
soap and water solution. Do not use open flame for
leak testing.
Air Shutter Settings
Opening
Model
“A”
33RDVDSN
1/32” (1.0 mm)
33RDVDSP
3/8” (9.5 mm)
36RDVDSN
1/32” (1.0 mm)
36RDVDSP
3/8” (9.5 mm)
39RDVDSN
1/32” (1.0 mm)
39RDVDSP
3/8” (9.5 mm)
NOTE: These are minimum settings. Air shutter open-
ings may be increased to prevent flame sooting.
ings may be increased to prevent flame sooting.
T203
Air shutter
12/12/03 djt
T203
Opening
“A”
“A”
Fig. 51 Air shutter opening.
Conversion Kits
Change Natural Change Propane
Model
to Propane
to Natural
33RDVDSN
20007864*
--
33RDVDSP
--
36RDVDSN
20007891*
--
36RDVDSP
--
39RDVDSN
20007903*
--
39RDVDSP
--
* Included with fireplace.
Normal and High
Direct Vent Units - Inputs - Orifice Size - Altitude
BTU/Hr
Manifold Pressure
Orifice 0 - 2000ft. Altitude in USA
Model
Max. Input
@ Max.
Orifice 0-4500ft Altitude in Canada
33RDVDSN
18,000
3.5”w.c.
#47 DMS
33RDVDSP
18,000
10.0” w.c.
#56 DMS
36RDVDSN
20,000
3.5” w.c.
#45 DMS
36RDVDSP
20,000
10.0” w.c.
#55 DMS
39RDVDSN
22,000
3.5” w.c.
#43 DMS
39RDVDSP
22,000
10.0” w.c.
#54 DMS