RDVDSN Series Direct Vent Gas Fireplace
20007894
A - Flat on wall  
B - Cross corner 
C -  **Island
D - Room divider 
E - Flat on wall corner 
F - Chase installation
Y - Refer to “Clearance to Combustibles” Section
Note (Fig. 2):  
** Island (C) and Room Divider (D) installation is possible as 
long as the horizontal portion of the vent system (X) does not 
exceed 20’ (6 m).  See details in manual Venting Section.
Locating Your Fireplace
Fig. 2 Locate gas fireplace.
LU584-T
Y
E
A
B
C
D
F
Y
B
X
LU584-R
Locating unit
2/23/01   sta
X
Top of Unit to Ceiling ................................ 36” (914 mm)
Front of Unit to Combustibles .................. 36” (914 mm)
Appliance
 
Top .......................................................... 0” (0 mm)
 
Bottom ..................................................... 0” (0 mm)
 
Side ......................................................... 0” (0 mm)
 
Back ........................................................ 0” (0 mm)
Venting
Concentric sections of DV Vent
 
Top, bottom & sides .............................. 1” (25 mm)
Rear Vent Applications 
 
Top ........................................................ 2” (51 mm)
 
Sides and Bottom .................................. 1” (25 mm)
Flex Vent .................................................. 7/8” (22 mm)
Mantels
The height that a combustible mantel is fitted above the 
fireplace is dependent on the depth of the mantel. This 
also applies to the distance between the mantel leg (if 
fitted) and the fireplace.
For the correct mounting height and widths refer to 
Figures 3a and 3b.
The fitting of a bay window trim kit does not effect 
the distances and reference points referred to in the 
diagram and chart.
Noncombustible mantels and legs may be installed at 
any height and width around the appliance. 
When using paint or lacquer to finish the mantel, such 
paint or lacquer must be heat resistant to prevent 
discoloration.
Clearance to Combustibles
A B C D E
V
W
X
Y
Z
Fireplace
CFM146
DV Mantel Chart
7/5/01   sta
CFM146
Fig. 3a  Combustible mantel minimum installation.
Top Louvre 
Assembly
Top of Combustion 
Chamber
Bottom of Door Trim
   
Mantel Shelf 
 
Mantel from Top 
 Ref.  or Breast Plate  Ref. 
of Combustion Chamber
   
Depth 
 
36/39/RDVDSN  33RDVDSN
  V 
10” (254 mm) 
19” (483 mm) 
17” (432 mm)
  W 
8” (203 mm) 
17” (432 mm) 
15” (381 mm)
  X 
6” (152 mm) 
15” (381 mm) 
13” (330 mm)
  Y 
4” (101 mm) 
13” (330 mm) 
11” (279 mm)
  Z 
2” (51 mm) 
11” (279 mm) 
9” (229 mm) 
Mantel Chart
 
 
Mantel 
 
Mantel Leg from Side
  Ref. 
Leg Depth 
Ref. 
of Comb. Opening
 
10” (254 mm) 
11¹⁄₂” (292 mm)
 
8” (203 mm) 
9¹⁄₂” (241 mm)
 
6” (152 mm) 
7¹⁄₂” (191 mm)
 
4” (101 mm) 
5¹⁄₂” (140 mm)
 
2” (51 mm) 
3¹⁄₂” (89 mm)
Fig. 3b  Combustible mantel leg minimum installation.
CFM170
J
F
G
H
I
Mantel
Leg
CFM164a
Mantel Leg Chart
06/22/01   sta
Black 
Surround 
Face
CFM170
DV Builder Front 
View
O
N
M
L
K
Side of 
Combustion Chamber