temco-tool 36tdvn 用户手册

下载
页码 44
37
TDVN Series Direct Vent Gas Fireplace
20007636
FK24 Fan Assembly
This auxiliary fan system increases the efficiency of the 
circulation of the heating air.
The FK24 fan kit allows variable speed control of the 
circulation fan and also incorporates a heat sensor in 
the circuit.
Specifications
115 Volt / 60Hz / 56 Watts 
Maintenance
The fan itself does not require regular maintenance, 
however periodic cleaning of the fan and the 
surrounding area is required.
Check the area under the control door (lower louvre 
assembly) and in front of the fan and wipe or vacuum this 
area at least once a month during the operating season.
Installation
The fan assembly and other components are supplied 
fully wired eliminating the need for a licensed electrician 
to carry out the installation.
If hard wiring the fan using Method B (following), we 
strongly recommend the use of a licensed electrician.
1.  Open the lower louvre assembly. Maneuver the fan 
& bracket assembly around the gas valve and lines 
to locate the unit onto the screw studs on the back of 
the fireplace.
2.  Install the thermal sensor under the bottom of the of 
the firebox, locating it over the two 10 mm studs and 
secure it with nuts.
3.  Locate the fan speed control unit. This can be fitted 
behind the lower louvre assembly as in Figure 52 
or located remotely in a conveniently located wall 
mounted electrical box. Remote location of the 
speed control will require suitable extension of the 
component wiring.
4.  The power supply may be connected in two ways:
  Method A
  Route the 6’ lead fitted to the unit to a conveniently 
located wall socket.
  Method B (Using EB-1 Receptacle Box)
  The EB-1 receptacle box (Pt. # ZA1200) may be 
hard wired into the house supply. The fan lead is 
then plugged into the EB-1 box. For instruction on 
wiring the EB-1 Electrical Junction Box see the 
earlier chapter in the Installation section of this 
manual.
FK12
This auxiliary fan system increases the efficiency of the 
circulation of the heating air. 
The FK12 Fan Assembly is a fixed speed fan system 
and does not allow for variable speed control. It does 
not use the speed control unit or the heat sensor used 
in the FK24 Kit.
Specifications
115 Volts / 60 Hz / 56 Watts.
Maintenance
The fan itself does not require regular maintenance, 
however periodic cleaning of the fan and the 
surrounding area is required. 
Check the area under the control door (lower louvre 
assembly) and in front of the fan and wipe or vacuum this 
area at least once a month during the operating season.
Installation
The fan assembly is supplied fully wired eliminating the 
need for a licensed electrician to carry out the installation.
1.  Open the lower Louvre assembly. Maneuver the 
fan & bracket assembly around the gas valve and 
lines to locate the unit against the back wall of the  
appliance, resting on the base.
2.  With the protective cover removed from the self-
adhesive ‘Velcro’ strips apply mild pressure to the 
fan & bracket unit to secure the strips to the metal 
panels. No further securing is required. 
3.  Power to the fan can be supplied by plugging the 
supplied lead into a conveniently located wall socket 
or by using a hard-wired EB-1 connector box.
Optional Accessories
Fan Kits
FP1230
FK24
fan install
11/02
Thermal Sen-
sor
Fan Speed 
Switch
Gas 
Lines
EB-1 
Receptacle 
Box
Fan
FP1230
Fig. 52  FK24 fan placement.