TDVN Series Direct Vent Gas Fireplace
20007636
Troubleshooting
SIT Millivolt Valve
NOTE: Before troubleshooting the gas  control system, be sure external shut off is in the “ON” position.
WARNING: Before doing any gas control service work, remove glass front!
  Table 1
 
Valve Type 
Main Operator 
Safety Magnet
 
NOVA MV Plus 
Minimum Voltage 
145mV 
Hold-in Current 
Less than 285mA
 
 
Coil Resistance 
2.25Ω ± 0.5Ω 
Drop-out Current 
Greater than 125mA
 
 
 
 
Coil Resistance 
0.108Ω ± 0.003Ω
  Problem 
Possible Cause 
Solution
  Pilot will not light. 
Air in gas lines. 
Bleed all air from gas lines.
   
Wrong inlet pressure. 
With the main burner functioning, adjust the inlet pressure   
   
 
regulator to supply gas to the appliance within the design    
   
 
parameters of the appliance manufacturer.  (Typically 7”NG,  
   
 
11”LPG).
   
Defective spark electrode. 
Replace piezo wire if insulation is cracked or the tip is cor   
   
 
roded.
   
 
Verify that the spark gap between the pilot and the electrode  
   
 
is correct.
   
Defective piezo wire. 
Replace piezo wire if insulation is damaged, or the wire is  bro 
   
 
ken or corroded.
   
Safety interlock function engaged.  Allow thermocouple to cool until the mv drops below the hold- 
   
 
in requirements of the safety magnet, (30 seconds or less).   
   
 
Re-light pilot.
  Pilot will not hold. 
Wrong inlet pressure.  
With the main burner functioning, adjust   the inlet pressure  
   
 
regulator to supply gas to the appliance  within design  
 
   
 
parameters of the appliance manufacturer. (Typically 7”NG,  
   
 
11”LPG)
   
Pilot adjustment screw not  
After the pilot has been lit for approximately three minutes,  
   
properly adjusted. 
and only the thermo-generator wire connected to the main  
   
 
operator head, measure the voltage across TPTH and TP.   
   
 
This open circuit voltage should be between 500mv and    
   
 
750mv. Tune the pilot adjustment screw until the mv reading  
   
 
falls within these parameters. (Counter-clockwise increases  
   
 
mv reading, clockwise decreases).
   
Thermocouple or  
Make certain that the thermocouple and thermo-generator are  
   
thermo-generator not properly  
fully inserted and tightened into their receptacles in the pilot  
   
inserted into the pilot housing. 
head. The thermocouple should be threaded into the valve  
   
 
hand-tight, plus 1/4 turn with a wrench.
   
Thermocouple or  
With the thermocouple and thermo-generator tips cool, clean  
   
thermo-generator has film  
the upper 3/8” with a very fine emery cloth. 
 
 
   
build-up on tip.
   
Electrical resistance too high. 
Using a very fine emery cloth, clean thermo-generator and  
   
 
thermocouple connections at valve. Tighten thermocouple into  
   
 
valve hand-tight, plus 1/4 turn with a wrench.
   
Defective thermocouple. 
Verify that thermocouple is not kinked or damaged. Check   
   
(mv Plus systems) 
open circuit voltage of thermocouple. Voltage should be    
   
 
between 18mv and 28mv. If voltage is less than 14mv,  
 
   
 
replace thermocouple.
System Checks