Silex Technology SX-200 用户手册

下载
页码 80
 
 
User’s Guide 
Document #40182-420  Rev. A 
 
47 
 
sample output: 
Port     Q-Size     Type      Attributes 
 *S1          0   serial      115200 N 8 1 XON/XOFF RS232 
 
 
SET PORT 
 
Sets Parameters for specified port.  The available commands are dependent on the port type.  
 
 
 CLEAR PORT S1 JOB  
 
This command aborts the currently active job on the port specified.  If the remote host is still connected, any further 
data received will be discarded.  
 
CL PORT S1 JOB 
 
 
 SET PORT S1 FLOW 
  
 
Set serial port flow control to NONE, XON/XOFF, CTS, or DSR 
 
SET PORT S1 FLOW <flow> 
 
(default = None) 
 
 
  SET PORT S1 PARITY 
 
Set serial port parity to NONE, EVEN, ODD, MARK, or SPACE 
 
SET PORT S1 Parity <parity> 
 
(Default = None) 
 
 SET PORT S1 SIZE 
 
Sets the data bits on the serial port 
 
 
SET PORT S1 Signal [7 | 8] 
 
(default = 8) 
 
 
 SET PORT S1 SPeed 
 
Sets serial port baud rate. Options for BAUD are 300, 600, 1200, 2400, 7200, 9600, 19200, 38400, 57600, 115200, 
230400, and 460800 
 
SET PORT S1 SPEED <baudrate> 
 
(default = 115200) 
 
 
 SET PORT S1 STOP 
 
Sets serial port stop bits per character. 
 
SET PORT S1 STOP [1 | 2] 
 
(default = 1)