Silex Technology SX-200 用户手册

下载
页码 80
 
 
User’s Guide 
Document #40182-420  Rev. A 
 
53 
 
Service Commands 
 
SET SERVI <service name> BOT   
  
Set beginning of transmission (BOT) string index for service 
 
SET SERVI <service name> BOT   nn 
 
(default = 1) 
 
 
SET SERVI <service name> EOT 
   
Set end of transmission (EOT) string index for service 
 
SET SERVI <service name> EOT  nn    
 
(default = 1) 
 
 
SH SERVI STRings [string_num
 
Defines the BOT and EOT strings used in services. If string_num is provided then the specific string definition and 
expansion is displayed.  If string_num is not provided, then all string definitions (but not their expansions) are 
displayed. 
 
sample output: 
10: \FF\04\FF\05\FF\06\FF\08 
 
 
 
SET SERVI <service name> FIlter   
 
Set filter index for service 
 
SET SERVI <service name> FIlter  nn 
 
 
 
    
 
SH SERVI FILters 
 
Shows filter settings 
  
sample output: 
 #  Service Name                        Filter 
  1 SLX_FFFFFF                         0: No Filter 
  2 BINARY_P1                          0: No Filter 
  3 TEXT_P1                            1: Text Substitution m= LF, r= 
CRLF 
  4 SLXFFFFFF_P1_4                    0: No Filter 
  5 SLXFFFFFF_P1_5                    0: No Filter 
  6 SLXFFFFFF_P1_AT                   4: PostScript Tagged Binary 
 
 
SET SERVI <service name> FMS