     Model #
  DC Voltage       Current (continuous)        Current (peak)
      Current Output (maximum charge)
        PCB Size
       6, 12
1.5A
   2.0A
         6 V = 200mA,  12 V = 400mA
  2
7
/
8
” x 2
1
/
4
” x 1”
(73 x 57 x 25 mm)
    6, 12, 24
1.5A
   2.0A
6 V = 180mA,  12 V = 350mA, 24 V = 700mA
  2
7
/
8
” x 2
1
/
2
” x 1
3
/
8
(73 x 64 x 35 mm)
    6, 12, 24
2.5A
   3.0A
6 V = 180mA,  12 V = 350mA, 24 V = 700mA
  3
3
/
8
” x 2
7
/
8
” x 1
5
/
16
(81 x 73 x 33 mm)
    6, 12, 24
4.0A
   5.0A
6 V = 180mA,  12 V = 350mA, 24 V = 700mA
  3
3
/
4
” x 2
7
/
8
” x 1
9
/
16
(95 x 73 x 40 mm)
    6, 12, 24
7.0A
   7.5A
6 V = 180mA,  12 V = 350mA, 24 V = 700mA
  5
1
/
2
” x 5
1
/
8
” x 2
11
/
64
(140 x 130 x 55 mm)
    6, 12, 24
9.0A
   10.0A
6 V = 180mA,  12 V = 350mA, 24 V = 700mA
  5
1
/
2
” x 5
1
/
8
” x 2
11
/
64
(140 x 130 x 55 mm)
Note: Products with model number that ends with "Q"or have a green “Q” sticker represents RoHS compliant products.
ST-2406-2AQ shown
ENFORCER
®
Installation Manual
ST-series
Power Supplies/Chargers
Features:
• Automatic recharging of back-up batteries.
• Several models to choose from.
• Programmable DC voltage output.
• Built-in battery short-circuit protection.
• Fused output for a regulated charge.
• Automatic switch-over to the backup battery if main power is lost or cut.
• LEDs indicate power status.
• Includes foam tape and battery leads for easy installation.
• Regulated and filtered output voltage.
What it is:
SECO-LARM’s ST-series of power supplies/chargers ensure that alarm systems and access control systems always have
enough power to do their job. Protected by fused output, input polarity protection diodes, and back-up battery polarity
reverse protection, these power supplies/chargers can be used to maximize the security and efficiency of nearly any alarm
or access control installation.
Fused Output:
The ST-1206-1.5AQ comes with a 3A fuse. The ST-2406-2AQ, ST-2406-3AQ, and ST-2406-5AQ models come with a 5A
fuse. The ST-2406-7AQ and ST-2406-10AQ come with a 10A  fuse. Use only the correct fuses to prevent short circuits
and damage to the power supplies/chargers or the alarm access control panel.
WARNING:
Connect these power supplies/chargers only to a rechargeable back-up battery. Use of a non-rechargeable back-up
battery could result in damage to the power supplies/chargers or the alarm access control panel, as well as leakage or
explosion of the battery.
 Installation:
 1. Mount the PC board in the desired location or enclosure. It must be easily accessible for future servicing.
 2. DC Power Output Setting:
a. To program ST-1206-1.5AQ DC voltage output:
1. 6VDC — Cut the wire loop, and connect to a 12VAC/20VA  transformer.
INSULATE THE CUT WIRE LEADS so that they do not come in contact with the power supplies/chargers.
2. 12VDC — Leave the wire loop uncut, and connect to a 16VAC/40VA transformer.
ST-1206-1.5AQ
ST-2406-2AQ
 
ST-2406-3AQ
ST-2406-5AQ
 
ST-2406-7AQ
ST-2406-10AQ
b. To program ST-2406 Series DC voltage output:
1. Set the desired DC output voltage ( 6, 12, or 24 VDC ) of the power supply using the DIP switch.
See Table 2.
2. The default voltage output setting is 12 VDC.