SECO-LARM USA enforcer st-2406-7aq 用户手册

下载
页码 2
SECO-LARM
SECO-LARM
SECO-LARM
SECO-LARM
SECO-LARM
®
 U.S.A., Inc.,
 U.S.A., Inc.,
 U.S.A., Inc.,
 U.S.A., Inc.,
 U.S.A., Inc., 16842 Millikan Avenue, Irvine, CA  92606
Tel: 800-662-0800 / 949-261-2999   Fax: 949-261-7326
Website: www.seco-larm.com
E-mail: sales@seco-larm.com
MuST12-2406Q_084.pmd
Order Part #763-074-8%
PITSW1
WARRANTY: 
This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to
the original consumer customer.  SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty
installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option.   In no event shall SECO-LARM be liable
for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
NOTICE:
 
 The information and specifications printed in this manual are current at the time of publication.  However, the SECO-LARM policy is one of continual development and
improvement.  For this reason, SECO-LARM reserves the right to change specifications without notice.  SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2008 SECO-LARM U.S.A., Inc.  All rights reserved.  This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
Transformer selection table:
To program DC voltage output:
NOTE:
a. Before connecting any external devices, temporarily power up the unit and measure the DC output voltage
to avoid damage to devices. Then disconnect power before connecting external devices.
b. LED status —  for ST-1206-1.5AQ, Red LED on indicates connections to AC power.
 for ST-2406 series, see Table 3.
WARNING:1. Using a higher AC input than recommended may damage the unit.
2. When a power supply/charger is used at its maximum load for an extended
period of time, the heatsink portion of the power supply/charger will be very hot.
3. DO NOT USE METAL SPACERS TO MOUNT THE POWER SUPPLY’S PC BOARD.
4. Measure DC output before connecting devices.
Table 3:
   Green LED        Red LED
Status
 ON
   ON
Normal
 OFF
   ON
No VAC input
 ON
   OFF
No VDC output
 OFF
   OFF
No VAC input and VDC output
LED status for ST-2406 series:
* For ST-1206-1.5AQ model. See point 2 under Installation.
 3. Connect the wirings to their respective terminals (see Figure 1 and 2).
Voltage
6V
ON
12V
24V
 OFF
OFF
 SW1
SW2
OFF
OFF
ON
 6VDC
12VDC
 24VDC
12VAC/20VA
16VAC/40VA
24-28VAC/210VA
ST-UV24-W50Q
24VAC/50VA
ST-UVDA-W100Q
 24-28VAC/100VA
  ST-UVDA-W100Q
24-28VAC/100VA
ST-2406-3AQ
16VAC/100VA
ST-UV16-W100Q
16VAC/100VA
  ST-UVDA-W180Q
ST-UV16-W100Q
ST-UVDA-W180Q
24-28VAC/180VA
24-28VAC/180VA
24-28VAC/180VA
ST-UVDA-W180Q
ST-UVDA-W180Q
24-28VAC/180VA
ST-UVDA-W180Q
24-28VAC/180VA
28VAC/350VA
ST-2406-5AQ
ST-2406-7AQ
ST-2406-10AQ
ST-2406-2AQ
Output voltage
To back-up battery positive (+) input
To back-up battery negative (-) input
To alarm or access control
panel VDC negative (-) input
To alarm or access
 control panel VDC
    positive (+) input
To alarm or access control
panel VDC negative (-) input
   AC
   DC
   BAT
     +
     -
     +
     -
Figure 2 – ST-2406 Series wiring diagram
  To Class-II
 transformer
VAC outputs
Red DC Output LED
   Green AC Input LED
Figure 1 – ST-1206-1.5AQ wiring diagram
To alarm or access control
panel VDC positive (+) input
  AC
  DC O/P
  I/P
     1
     2
     3
     4
(black)
(red)
  To Class-II
 transformer
VAC outputs
Wire loop
 
Red Led
indicator
ST-1206-1.5AQ
12VAC/20VA
16VAC/40VA
ST-UV24-W50Q
24VAC/50VA
N/A
To back-up battery negative (-) input
To back-up battery positive (+) input
ST-UV28-T350Q
Table 1:
Table 2: