MODEL: T21004R
IN RAINPROOF (TYPE 3R) ENCLOSURE FOR INDOOR/OUTDOOR USE 
60 AMP 120/240 VOLT OR 120/208 VOLT SINGLE PHASE, (THREE WIRE) AC
The short circuit rating of this panel is 10000 symmetrical amperes.
IMPORTANT: 
This control panel must be installed according to the National Electrical Code (including article 
680) or Canadian Electrical Code (including section 68) and local code requirements.  This installation is subject to the approval
by the local inspection authority. The main lugs and neutral main are suitable for No. 14 to 2 AWG COPPER conductors. Use
No. 14 to 6 AWG COPPER conductors for branch circuit wiring. Follow gauge selection table and corresponding terminal screw
tightening torque requirements below. Install interchangeable circuit breakers with an interrupting current rating of 10000 
symmetrical amperes, or higher. All circuit breakers in this control panel shall be of the same manufacturer and type. See list of
suitable types below. Follow manufacturers instructions for installing and testing of ground fault circuit breakers (GFCB) and
interrupters (GFCI). Install only LISTED receptacle(s) and/or wiring device(s) inside the enclosure. A LISTED wiring device may
be installed in the rectangular side knockout provided. When panel is outdoors, a LISTED rainproof cover must be installed over
the wiring device in the side knockouts. If this enclosure is used for direct conduit connection to a wet-niche or no niche 
luminaire, one of the connection kits listed below in Note 5 must be used. This control should not be connected to any 
equipment which would cause bodily injury or property damage should it be activated unexpectedly. After wiring, install front
panel over wiring compartment and close unused breaker openings with filler plates. 
KEEP DOOR CLOSED AT ALL TIMES.
CLASS CTL DISTRIBUTION /CONTROL 
PANEL WITH TIME SWITCH
LR3730
UL 508
UL1563
NOTES: 
1. Any Intermatic T100M or ET100CM series Time Switch, PF1000M 
Series freeze protection or RC2000M Series air switch mechanism
may be installed in the bracket provided or in the event an existing 
mechanism is replaced.
2. If this control panel requires bonding, attach a LISTED bonding
terminal of a suitable size using the mounting hole(s) provided on the 
bottom of the enclosure (156T11047A may be ordered).
3. When a back-fed breaker is used in this control panel, order 
22T904A to comply with NEC article 384-16 (g).
4. Wiring devices may be installed in this control panel (order 21T156A
(4) Standoffs for mounting).
5. The following kits are available to connect under water luminaires to this 
enclosure:
1/2” non-metallic - order 156PA13713A
3/4” non-metallic - order 156PA13714A
1” non-metallic - order 156PA13715A
1/2” metallic - order 156PA14336A
TIME SWITCH RATINGS: 
30 AMP. RESISTIVE, INDUCTIVE, TUNGSTEN OR 1000 VA PILOT DUTY -
120/208/240 VOLT A.C. 2 HP (24 FLA)-120 VOLT A.C., 
5 HP (28 FLA)-240 VOLT A.C.
CLOCK MOTOR: 208-277 VOLTS 60 HZ.
(To order clock motor replacement, specify part no. WG--on motor cover)                   
TIME SWITCH OPERATING INSTRUCTIONS
1. TO SET "ON" AND "OFF" TIMES:
Hold TRIPPERS against edge of CLOCK-DIAL,  pointing to time (AM or PM)
when ON and OFF operations are desired. Tighten tripper  screws firmly.
2. TO SET TIME-OF-DAY:
Pull CLOCK-DIAL outward. Turn in either direction
and align the exact time-of-day on the CLOCK-DIAL
(the time now, when switch is being put into opera-
tion) to the pointer.
-DO NOT MOVE POINTER-
• TO OPERATE SWITCH MANUALLY: Move MAN-
UAL-LEVER below left or right as indicated by
arrows. This will not affect the next operation.
• FOR MORE THAN ONE DAILY ON-OFF OPER-
ATION: Place additional tripper pairs on CLOCK-DIAL (order 156T1978A). 
• IN CASE OF POWER FAILURE: Reset CLOCK-DIAL to proper time of day.
See step 2 above.
ON
TRIPPER
TIME
POINTER
TIME
DIAL
OFF
TRIPPER
MANUAL
LEVER
IIN
NT
TE
ER
RM
MA
AT
TIIC
C IIN
NC
CO
OR
RP
PO
OR
RA
AT
TE
ED
D
SPRING GROVE ILLINOIS 60081-9698
158TP12178  
SUITABLE FOR SWIMMING POOL / SPA APPLICATIONS AND FOR DIRECT CONDUIT CONNECTION TO A WET-NICHE OR NO NICHE LUMINAIRE.
*
TORQUE CIRCUIT BREAKER LUGS TO VALUES SPECIFIED ON 
CIRCUIT BREAKERS
WIRING INFORMATION - COPPER CONDUCTORS ONLY
TERMINAL TORQUE*
GENERAL
GENERAL
PURPOSE
MAX MOTOR
PURPOSE
BRANCH
SUPPLY
LINE AND
LOAD
BRANCH
CIRCUIT
WIRE SIZE
CIRCUIT
NEUTRAL NEUTRAL (CONTINUOUS
CIRCUIT
MAXIMUM
75˚C MIN
BREAKER
MAIN
AND
DUTY)
BREAKER
CURRENT
INSULATION
RATING
LUGS
GROUND 120V.     240V.
RATING
CAPACITY
AWG
AMP
LB-IN
LB-IN
HP        HP
AMP
AMP
14
15
35
20
1/2         1
15
12
12
20
35
20
1            2
20
16
10
30
35
20
1 1/2    3
30
24
8
50
40
25
2          5
40
32
6
60
45
35
---         ---
60
44
SUITABLE  LISTED BREAKERS
CIRCUIT BREAKER
FILLER
MANUFACTURER
SINGLE DOUBLE TWIN QUAD
GFCB
PLATE
CUTLER-HAMMER
BR
BR
BRD
BRD
GFCB
BRFP
MURRY
MP-T
MP-T
MH-T MH-T
MP-GT   LX100FP
SIEMENS
QP
QP
QT
QT
QPF
QF3
SQUARE D
HOM
HOM
HOMT HOMT
----
HOMFP
THOMAS & BETTS
TB
TB
TBBD TBBQ
GFB      FP-1C-TB