Parker Hannifin 192-510011n7 用户手册

下载
页码 36
Accessories for HLE and HLEZ
Automation
30
Parker Hannifin GmbH
Electromechanical Division
Highly flexible, thin lines with a low bending strength should be loosely gathered together and routed in order in a protective
hose. When selecting the size of the protective hose, ensure that its area is considerably greater than the sum of the individual
cross-sectional areas. As a guide, allow approximately 10 % of the diameter of each line as clearance.
Load diagrams
Maximum suspended length vs. additional load
Maximum length with permitted deflection vs. additional load
1
0
2
3
4
5
0
1
2
3
0.625
0.450
0.320
0
2
4
6
suspended length
L
f
 in m
stroke L
S
 in m
additional load q
z
in kg/m
L
S
L
f
0.625
0.450
0.320
0
1
2
3
0
2
4
6
0
1
2
3
4
5
Length with
deflection L
D
 in m
Stroke L
S
 in m
additional load q
z
in kg/m
L
D
L
S
KR
KR 52 94 150
4
8
KR 200
300
Determining the chain length
Suspended chain
Chain with permitted deflection
0.320: rounded to a multiple of 32 mm
0.320: rounded to a multiple of 32 mm
0.450: rounded to a multiple of 45 mm
0.450: rounded to a multiple of 45 mm
%
6
.
/
/
/
 
0.625: rounded to a multiple of 62.5 mm
%
6
.
/
.5
/
/
 
0.625: rounded to a multiple of 62.5 mm
Longitudinal flange connection set (option V)
Longitudinal flange plates make it possible to move more than the standard available stroke. A flange connection is always
necessary if the maximum travel path is exceeded (refer to Technical data, pages 6 and 20). Profile sections should normally
be split equally, with the separation point close to a fixing point. The bearing distance should generally be between 1.0m and
1.5m. If a longitudinal flange connection is used to extend the travel distance, the load data must be reduced as shown in the
table below. An HLE with a longitudinal flange connection should only be installed with the profile aperture in the top or the
bottom.
Unit
HLE80
HLE100
HLE150
HLEZ100
HLEZ150
maximum permitted load
N
0.5 x Fx
*1
0.5 x Fx
*1
0.5 x Fx
*1
Speed
m/s
< 1
< 1
< 1
Acceleration
m/s
2
< 1
< 1
< 1
Repeatability
mm
> ±0.5
> ±0.5
> ±0.5
unchanged
*1. Fx-HLE: refer to page 7;
A
A
Section A-A
FL
FB
HB
FD
Model / size
Type
FL
FB
FD
HB
HLE80
LVS80
300
70
15
80
HLE100 / HLEZ100
LVS100
400
90
15
100
HLE150 / HLEZ150
LVS150
500
130
15
150