Mains Input Voltage 
100V, 110V, 120V, 220V, 230V or 240V AC at 50Hz or 60Hz 
(Set within the 6160 at time of manufacture) 
Dimensions 
Width .............................................................................................. 482mm (19.0”)
Height ............................................................................................... 176mm (6.9”)
Depth .............................................................................................. 460mm (18.1”)
(not including feet, terminals and handles)
Fuse Ratings 
Mains input fuse
 
100 – 125V: ......................................................................... 2SB slow blow 15A
200 – 250V: ......................................................................... 2SB slow blow 10A
(user serviceable)
Internal DC rail fuses..................................................12 x 2AG normal acting 6A
(NOT user serviceable)
Weight 
Net: ................................................................................................. 30.0kg (66.1lb)
Gross:.............................................................................................. 34.0kg (74.8lb)
Specifications 
Explained 
Rated Power Output 
(per channel)
................................................ 160W
RMS 
into 8Ω
The 6160 has been designed around the industry standard 8Ω load.  The 6160
delivers a staggering 160W
RMS
 continuously into 8Ω loads and 225W
RMS
 into
4Ω loads.  The 6160 will also handle complex and 2Ω loads with stability and
ease when operated in NORMAL mode.  Load impedances lower than 8Ω are
not recommended when operating in BRIDGED mode. 
Frequency Response ........................................................ 5Hz to 40kHz, ±0.25dB
This is the “standard” specification with which everyone is familiar.  Actually,
“frequency response” is a misnomer: technically, it should be called “amplitude
response versus frequency” for it describes how uniform the amplitude or
strength of signals of various frequencies is maintained.  It is generally thought
that a difference of 1db is the least that can be perceived by ear.  To better that
by a wide margin, the 6160 is specified four times higher, thus far exceeding the
audible range of the human ear. 
Total Harmonic Distortion 
(THD+N)
.............................. 0.005%, @ 1kHz into 8Ω
Measurements are made with fixed, purely resistive loads.  However, since
speakers are not purely resistive, an amplifier’s distortion specifications do not
indicate what performance will be with the actual loads presented by speakers.
Perreaux distortion measurements hold for any conditions presented by any
known speaker.  Further, any measurable distortion in the Perreaux is second-
order harmonics – the least offensive to the ear. 
Voltage Gain......................................................................................................27.6dB
The amount of amplification the amplifier is asserting on the input signal.  Gain
can be calculated by dividing the rated output by the input sensitivity.