Motorola 82543 用户手册

下载
页码 73
B-4
Gigabit Ethernet/82543 PMC Installation and Use
B
!
Caution
Board Damage
Do not operate the product outside the specified environmental limits. 
High humidity, temperature and condensation may cause short circuits. 
Therefore, ensure that the product is completely dry and there is no 
moisture on any surface before applying power.
 lists environmental requirements for the Gigabit Ethernet/82543 
PMC Module.
Table 3-3.  Environmental Requirements 
Characteristic
Specification
Temperature range 
(at sea level)
Operating : 0°C to 55°C (32°F to 158°F) 
Nonoperating : -40°C to 85°C (-40°F to 185°F) 
Temperature 
change
Operating : 
±0.5°C (33°F) per minute 
Nonoperating : 
±1.0°C (34°F) per minute 
Air flow
200 linear feet per minute (LFM) 
Relative humidity
Operating : 5% to 95% @ 40°C (104°F) to 55°C (131°F) 
— noncondensing
Nonoperating : 5% to 95% @ 40°C (104°F) to 55°C 
(131°F) — noncondensing
Altitude
Operating : -300 m to +3000 m
Nonoperating : -300 m to +13000 m
Shock
Operating : 5 G / 11 ms halfsine — applied once in either 
direction of three orthogonal axes
Nonoperating : 15 G / 11 ms halfsine — applied once in 
either direction of three orthogonal axes
Vibration
Operating : 10 to 15 Hz, 2 mm amplitude —  15 to          
150 Hz, 2G
Nonoperating : 10 to 15 Hz, 5 mm amplitude — 15 to 
150 Hz, 5G
Free fall
Operating : 100 mm / 3 axis
Nonoperating : 1200 mm / all edges and corners
Radiated emissions FCC Class A, CISPR-22 Class A (dated 1998), CISPR-
24 (dated 1998), CE Mark Class A, UL/cUL Recognized 
Component