Motorola LS4208 用户手册

下载
页码 360
User Preferences
4 - 9
Laser On Time
This parameter sets the maximum time that decode processing continues during a scan attempt. It is 
programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default Laser On Time is 3.0 seconds.
To set a Laser On Time, scan the bar code below. Next, scan two numeric bar codes beginning on 
 in 
 that correspond to the desired on time. Single digit numbers must have a leading 
zero. For example, to set an On Time of 0.5 seconds, scan the bar code below, then scan the “0” and “5” bar 
codes. If an error is made, or the selection needs to be changed, scan Cancel on 
Beep After Good Decode
Scan a bar code below to select whether or not the scanner beeps after a good decode. If Do Not Beep After 
Good Decode 
is selected, the beeper still operates during parameter menu scanning and indicates error 
conditions.
Laser On Time
*
Beep After Good Decode
(Enable)
Do Not Beep After Good Decode
(Disable)