Mr. Heater TS125FAV 用户手册

下载
页码 20
Color
Length
From
To
Yellow
18" (406mm)
High Limit
Ignition Control Temp. Terminal
Yellow
18" (406mm)
High Limit
Ignition Control Temp Terminal
55FAV, 85FAV, 125FAV
WIRING CHART (Wire: Type AWG 150
o
 C or equivalent (Type SF2-200, **SGI-250
o
 C))
WIRING DIAGRAMS
8
Operating Instructions and Owner’s Manual
Enerco Group, Inc.| Forced Air Propane Construction Heater
70056   Rev. C   4/07
HIGH LIMIT
SWITCH
MOTOR
THERMOCOUPLE
TO WIRE
IGNITION CONTROL
TEMP
MOTOR
VAC INPUT
HV TRANS
GND
SCREW
G
W
B
LINE CORD
O**
G
SPARK PLUG
Y
B
Y
B
VAC INPUT
MOTOR
TEMP
HV TRANS
IGNITION
CONTROL
TO WIRE
TO WIRE
115V
60HZ
TO JUNCTION
SPARK
PLUG
HIGH LIMIT
SWITCH
GND
SCREW
TEMP
MOTOR
VAC INPUT
MOTOR
B
W
COLOR CODE
LEGEND
B   BLACK
W   WHITE
G   GREEN
R   RED
Y   YEL
O   ORG
FEMALE CONN.
RING CONN.
CONNECTION DIAGRAM
SCHEMATIC DIAGRAM
NOTE:
If any original wiring as supplied with the heater, must be replaced, It must be replaced with
Type AWG 105° C wire or its equivalent, except as indicated (Type SF 2.200, **SGI-250° C)