Multi-Tech Systems MTA128NT 用户手册

下载
页码 66
Introduction and Description
MTA128ST/NT
        8
LED Indicators
 The ten LED indicators on the front panel (see figure below) of the MTA128ST/NT report status and line
activity.
TD
 Transmit  Data
Flashes when data is being transmitted (on for a space, off for a mark).
RD
 Receive Data
Flashes when data is being received (on for a space, off for a mark).
LS
 
Link Status
For EuroISDN NET3, INS64, and VN4 switch protocols, lights when the TA is turned on. For US NI-1, DMS-100,
and AT&T 5ESS switch protocols: On Steady, Link with central office is established (requires correct configuration
of SPIDs) Flashing, Physical layer is down or one or both SPIDs have not been verified with central office
B1
 
Bearer Channel 1
When lit, indicates active data or voice connection on bearer channel 1.
B2
 Bearer Channel 2
When lit, indicates active data or voice connection on bearer channel 2.
TR
 Terminal  Ready
Lights to indicate that the computer is communicating with the MTA128ST/NT, so the MTA128ST/NT can answer
an incoming call.
OH
 
Off Hook
Lights when analog equipment on AUX port is active or off-hook.
128
 
128 Kbps
Lights to indicate that the B channels have been multiplexed into a single 128 Kbps communications link.
P1
 
Data Protocol
Lights in combination with P2 and 128 LEDs to indicate which data protocol (V.110, V.120, X.75, PPP, MLPPP) is in
use as shown in the table below.
P2
 Data Protocol
Lights in combination with P1 and 128 LEDs to indicate which data protocol (V.110, V.120, X.75, PPP, MLPPP) is in
use as shown in the table below.