culligan 2 用户手册

下载
页码 15
3
recharge, grasp the white outer 24-
hour dial J and rotate until the desired
recharge time on the dial is opposite
the dot. Note: Whenever the time of
recharge is changed, the time-of-day
setting must also be changed follow-
ing above instructions. (When you
reset time-of-day, double check to be
sure that the time of recharge is not
accidently changed in the process.)
FREQUENCY OF RECHARGE
The frequency of recharge was
preset for your expected family needs
when the water conditioner was
installed.
There are six stainless steel tabs on a
numbered wheel F which program
recharge. When all six tabs are
pushed in, the unit will recharge
every day; if every other tab is in,
recharge will occur every other day;
if two opposite tabs are in, recharge
will be every third day; and if only
one tab is in, recharge occurs every
sixth day.
REMEMBER
Push IN to recharge, pull OUT to skip.
SALT ECONOMIZER
Has a dial E which controls the
pounds of salt used per recharge. This
was set at the time of installation.
Before making any changes, consult
your independently operated Culli-
gan dealer for advice on proper
setting, then make these adjustments:
Loosen screw A in the center of dial.
While holding cam gear stationery,
rotate the dial until desired salt
dosage in pounds is aligned with
mark D. Then tighten screw.
Used on SOFT-MINDER
®
 initiated
water conditioners. For information
regarding resetting of the number
of gallons between recharges,
contact your Culligan dealer.