hearth-and-home-technolog sl-350trs-ce-d 用户手册
Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07
10
A
B
C
D
E
7.6 cm
1.3 cm
A
B
C
D
E
86.4cm
41.3cm
72.8cm
100.1cm
141.6cm
*
Figure 2. Fireplace Dimensions, Locations, and
Space Requirements
3
Installing the
Fireplace
Fireplace
The diagram below shows space and clearance
requirements for locating a fireplace within a room.
requirements for locating a fireplace within a room.
Step 1
Locating the
Fireplace
Locating the
Fireplace
Figure 3. Heat Shield
NOTE:
Dimensions are
shown with the
sides, back
and/or corners
of the unit 1/2
inch from the
wall.
Dimensions are
shown with the
sides, back
and/or corners
of the unit 1/2
inch from the
wall.
The heat shield must be
attached as shown if
combustible materials
are placed directly on
top standoffs (Figure 3).
attached as shown if
combustible materials
are placed directly on
top standoffs (Figure 3).
The minimum clearance
to a perpendicular wall
extending past the face
of the fireplace is 7.62cm.
to a perpendicular wall
extending past the face
of the fireplace is 7.62cm.
The back of the fireplac-
es may be recessed
into combustible con-
struction, as shown
below.
es may be recessed
into combustible con-
struction, as shown
below.
MODEL: SL-350TRS-CE-D RECESSED DEPTH: 41.3cm
Clearance Requirements
The top and back of the
fireplace are defined by
stand-offs.
fireplace are defined by
stand-offs.
Minimum Clearances from the Fireplace to Combustible Materials
Glass
Front
Front
Floor
Back of
Fireplace
Sides of
Fireplace
Top of
Fireplace
Ceiling
91.4cm
0
1.3cm
1.3cm
3.8cm
79cm
TOP STANDOFFS
HEAT SHIELD
HEAT SHIELD
INSTALLED