Omron ethernet direct dr 170 14 用户手册

下载
页码 70
Klinkmann Automation Omron Ethernet DAServer 
 
 
Omron Ethernet DAServer Ver 1.x User Manual Rev 1.4                                                                 17014m14  
CHAPTER 1 
Introduction 
This chapter provides you with an overview of the KLINKMANN OMRON Ethernet Direct 
DAServer, including the application- and bus-level communications protocols, item 
naming  conventions and DAServer features. 
 
Contents 
• 
Overview 
• Communications Protocols 
• Accessing Items via the DAServer 
• Features 
• Demo Mode 
• Network Environment and Conditions  
 
Overview 
The KLINKMANN OMRON Ethernet Direct DAServer (hereafter referred to as the 
“OMRON Ethernet DAServer” or “DAServer” or “DASOmronEth” throughout the 
remainder of this user’s guide) is a Microsoft ® Windows ® application program that acts 
as a FINS message communications protocol server. It allows other Windows application 
programs access to data from OMRON PLCs (also referred to as devices) over the 
OMRON Ethernet FA (Factory Automation) network. 
 
The OMRON Ethernet Direct DAServer requires an Ethernet card and TCP/IP protocol 
installed on the computer to communicate with the Ethernet network. The OMRON 
Ethernet Direct DAServer can access to data from Controllers connected to the Ethernet 
System
 directly (with Ethernet Unit installed) or from Controllers interconnected to 
Ethernet System through SYSMAC LINK network or any other OMRON FA network 
(through PC Gateway - an OMRON Controller which has multiple Communications Units 
mounted, including the Ethernet Unit, and therefore that belongs to two networks and can 
thus function as an interface between them). The OMRON Ethernet Direct DAServer 
supports the Controller Memory Areas accessible by FINS commands
 
No additions to Controller’s user program are needed if OMRON Ethernet Direct 
DAServer is used in a poll (normal) mode, i.e. the DAServer sends read or write FINS 
command to Controller and Controller responds with corresponding response. The 
OMRON Ethernet Direct DAServer supports also the possibility to receive “unsolicited” 
data from Controller – in this case some additions in Controller program are needed. The 
DAServer “slave” mode can be established – at communication start-up DAServer 
requests data one time and after it - only unsolicited data can be received from Controller. 
At same time the writing of new values to Controller is still possible. 
 
The OMRON Ethernet Direct DAServer can access to data from CS1/CJ1, CV-series and 
C200HX/C200HG/C200HE PLCs (directly from Ethernet network or inter-networked from 
other OMRON FA networks) as well as from C-series and CQM1 PLCs (only inter-
networked from other OMRON FA networks).  
 
While the OMRON Ethernet Direct DAServer is primarily intended for use with 
Wonderware InTouch ® (Version 7.11 Patch 02 and later), it may be used by any