Hitachi L100 用户手册

下载
页码 192
L100 Inverter
T
roub
leshooting
and Maintenance
6–7
Trip History and Inverter Status
We recommend that you first find the cause of the fault before clearing it. When a fault 
occurs, the inverter stores important performance data at the moment of the fault. To 
access the data, use the monitor functions (D_xx) and select D_08 for details about the 
present fault (E
n
), or the error code for the past two trip events (E
n-1
 and E
n-2
) using the 
D_09 Trip History function.
The following Monitor Menu map shows how to access the error codes. When fault(s) 
exist, you can review their details by first selecting the proper function: D_08 displays 
current trip data, and D_09 displays trip history.
Monitor Menu
2
1
Error Code
Previous 
error #1
FUNC.
FUNC.
FUNC.
FUNC.
FUNC.
FUNC.
Error
exists?
Output frequency 
at trip point
Motor current 
at trip point
DC bus voltage 
at trip point
No error
Yes
No
FUNC.
Error
(n-1)
 
exists?
Yes
No
Error
(n-2)
 
exists?
Yes
No
Previous 
error #2
FUNC.
No
history
No
history
FUNC.
FUNC.
FUNC.
Trip History
2
1
2
2
Current Trip
Conditions
d
0 8
  E 0 9
d
0 1
d
0 9
  1 0.0
 0.25
 18 9.8
  _ _ _
  E 0 3
  _ _ _
  _ _ _
  E 0 5