Honeywell MK VIII 用户手册

下载
页码 326
Honeywell
MK VI  MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896
SCALE: NONE
SIZE: A
DWG NO: 060-4314-150
REV:
SHEET 
306
7.1.1.3  Mode 6 Callouts Discrete #1 (272)
Data:
 Discrete
Label:
 272 Octal
Significant Bits:
 (see table below)
Sign Bit:
 N/A
Transmit Interval:
100 msec  ± 10%
 BIT NO
WARNING MESSAGE (1 = voice on)
  11
 MINIMUMS
 * 12
 DECISION HEIGHT
 * 13
 APPROACHING MINIMUMS
 * 14
 APPROACHING DECISION HEIGHT
 * 15
 ZERO (Not supported)
  16
 TEN
  17
 TWENTY
  18
 THIRTY
  19
 FORTY
  20
 FIFTY
 * 21
 SIXTY
 * 22
 EIGHTY
  23
 ONE HUNDRED
  24
 TWO HUNDRED
 25
 THREE HUNDRED
 * 26
 MINIMUM
 * 27
 PLUS HUNDRED
 * 28
 DECIDE
 * 29
 FIFTY ABOVE
NOTE (*):  Bits 12 - 15, 21, 22 and 26 - 29 will be set to zero, Not supported.
7.1.1.4  Mode 6 Callouts Discrete #2 (273)
Data:
 Discrete
Label:
 273 Octal
Significant Bits:
 (see table below)
Sign Bit:
 N/A
Transmit Interval:
100 msec ± 10%
 BIT NO
DEFINITION (1 = voice on)
 11
 FOUR HUNDRED
  12
 FIVE HUNDRED (NORMAL, SMART or ABOVE FIELD)
 13
 ONE THOUSAND
 * 14
 700 HZ TONE
 * 15
 960 HZ TONE
 * 16
 1400 HZ TONE
 * 17
 2800 HZ TONE
  18
 BANK ANGLE (pause) BANK ANGLE
 * 19
 THIRTY FIVE
 * 20
 TWENTY FIVE  HUNDRED
 * 21
 RADIO ALTIMETER
 * 22
 FIVE
  23
 FIVE HUNDRED ABOVE (ABOVE FIELD)
 * 24
 (SPARE)
 * 25
 (SPARE)
 * 26
 (SPARE)
* 27
 FLAPS (pause) FLAPS
* 28
 AUTOPILOT
 * 29
 SPEED BRAKE (pause) SPEED BRAKE
NOTE (*):  Bits 14 - 17, 19 – 22, and 24 - 29 will be set to zero. Not supported.