14.37  Set Multiple (C6h)   
Command Block Output Registers 
  Command Block Input Registers 
Register 
7 6 5 4 3 2 1 0  Register 
7 6 5 4 3 2 1 0
Data 
- - - - -
-
-
-  Data 
- - - - - -
-
-
Feature 
- - - - -
-
-
-  Error 
...See 
Below... 
Sector Count 
V V V V V V V V   Sector Count 
-  -  -  -  -  -
-
-
LBA 
Low 
- - - - -
-
-
-  LBA 
Low 
- - - - - -
-
-
LBA 
Mid 
- - - - -
-
-
-  LBA 
Mid 
- - - - - -
-
-
LBA 
High 
- - - - -
-
-
-  LBA 
High 
- - - - - -
-
-
Device 
- - - - -
-
-
-  Device 
- - - - - -
-
-
Command 
1 1 0 0 0 1 1 0  Status 
...See 
Below... 
 
Error Register 
 
Status Register 
7 6 5 4 3 2 1 0 
 7 6 5 4 3 2 1 0 
CRC UNC  0 
IDN 
0  ABT  T0N
AM
 BSY RDY
DF DSC DRQ 
COR IDX
ERR
0 0 0 0 0 V 0 0 
 0 V 0 -  -  0 0 V 
Table 107 Set Multiple Command (C6h)   
The Set Multiple command enables the device to perform Read and Write Multiple commands and 
establishes the block size for these commands. The block size is the number of sectors to be 
transferred for each interrupt.   
The default block size after power up is 0, and Read Multiple and Write Multiple commands are 
disabled.  
If an invalid block size is specified, an Abort error will be returned to the host, and Read Multiple 
and Write Multiple commands will be disabled.   
Output Parameters To The Device 
Sector Count 
The block size to be used for Read Multiple and Write Multiple commands. Valid 
block sizes can be selected from 0, 1, 2, 4, 8 or 16. If 0 is specified, then Read Multiple 
and Write Multiple commands are disabled.