emergency unload occurs, as well as the problems cited in section 5.1, "Data loss by power off" on page 
19 and section 5.2, “Write Cache” on page 19. 
6.3.6.4   Test considerations 
Start/stop testing is classically performed to verify head/disk durability. The heads do not land on the disk, 
so this type of test should be viewed as a test of the load/unload function. 
Start/Stop testing should be done by commands through the interface, not by power cycling the drive. 
Simple power cycling of the drive invokes the emergency unload mechanism and subjects the HDD to 
nontypical mechanical stress. 
Power cycling testing may be required to test the boot-up function of the system. In this case HItachi 
recommends that the power-off portion of the cycle contain the sequence specified in section 6.4.6.2, 
"Required Power-Off Sequence” on page 29.    If this is not done, the emergency unload function is 
invoked and nontypical stress results.