Crestron clt-pws75 clx-pws75 用户手册

下载
页码 6
   
CLT- & CLX-PWS75
 
Terminal Block & Module Locations (Single-wide Enclosure) 
Functional Summary 
GROUNDING
TERMINAL
BLOCK
MODULE
TERMINAL
BLOCK
 
The Crestron 75 Watt Power Supply Terminal Block and 
Module (CLT-PWS75 and CLX-PWS75, respectively) 
are considered a single entity and must be used together. 
They ship separately to permit termination of the field 
wiring to the CLT-PWS75 prior to installation of the 
CLX-PWS75, as described in this guide. The  
CLX-PWS75 is a power supply module that provides up 
to 75 Watts of Cresnet power to Crestron equipment. The 
terminal block and module can be mounted in any 
Crestron Automation Enclosure (CAEN-Series 
Enclosures, see warning below). The terminal block is 
designed to terminate the circuit feed (HOT and 
NEUTRAL) and distribute the power to a connector on a 
supplied cable assembly (LOAD) that connects to the 
power supply module. The power supply module operates 
with an input of 100 to 250 VAC, 2.3A (maximum). The 
power supply module has a fuse that protects the 24 VDC 
output. If the network power lines are shorted, the fuse is 
blown. As a result, the NET POWER LED extinguishes.  
Industry Compliance 
This unit has been manufactured to comply with UL’s 
Standards for Safety in Canada and the United States. 
Formal approval is pending.  
Terminal Block & Module Locations (Double-wide Enclosure) 
Installation 
MODULE
TERMINAL BLOCK
(RIGHT)
GROUNDING TERMINAL BLOCKS
TERMINAL BLOCK
(LEFT)
MODULE
 
The terminal block and module must be mounted into a 
Crestron Automation Enclosure by a licensed electrician, 
in accordance with all national and local codes.  
CAUTION:  This equipment is for indoor use only and 
needs to be air-cooled. Mount in a well-ventilated area. 
The ambient temperature must be 32
°F to 104°F (0°C to 
40
°C). The relative humidity must be 0% to 90% (non-
condensing).  
CAUTION: Terminal blocks and modules must be 
installed in the lowest slot of an enclosure. The only 
devices in an enclosure that may be placed beneath the 
block and module is the Crestron PAC2 Automation 
Control System or CAEN-BLOCK Termination Block. 
Refer to the illustrations shown for recommended 
installation locations.  
Crestron Electronics, Inc.
 
Installation Guide – DOC. 6348
 
15 Volvo Drive   Rockleigh, NJ 07647
 
(2012603)
   
Tel: 888.CRESTRON
 
06.05   
 
Fax: 201.767.7576
  
Specifications subject to 
 
www.crestron.com
 