Launching Test Manager Independent of SIMPL Windows 
Test Manager can be opened independently of SIMPL Windows by selecting Test 
Manager from the Windows Start Menu. 
Screen Navigation 
Test Manager’s three subwindows are resizable, as is the entire Test Manager 
window. 
Test Manager 
 
Trace Window 
The Trace Window will display all the signals in a program as they change state or 
value. Digital signals that change state or analog signals change value, these signals 
will be displayed in realtime. To monitor analog and serial values, use the Status 
Window
.  
The exclusion list option (Trace Window | Exclude Signals From Trace Window
allows the user to select specific signals that they do not want to see in the Trace 
Window
. This is especially useful if a given program has certain signals that are 
transitioning rapidly. For example, a fast oscillator may be generating too many 
signals into the Trace Window, which makes it difficult to see relevant signal 
transitions. By eliminating the oscillator's signals, it will be easier to examine other 
parts of the program. The exclusion list is stored for a given program by using the 
base name of the program with the TM extension. For example, the program 
test.smw would have its exclusion list stored in the test.tm file. If a program has one 
or more signals in its exclusion list, an indicator displays the word "Exclusions" in 
the lower right hand corner of the status bar.  
Status Window 
The Status Window only monitors the activity of the signals specified by the 
programmer, in contrast to the Trace Window, which monitors every signal in the 
program. This is especially helpful if you want to monitor only two or three signals 
 Crestron SIMPL Windows 
Installation & Operations Guide – DOC. 5728C 