report them to Crestron along with a description of what you were doing when they 
occurred, and a saved version of your program both before and after the problem 
occurred. 
Errors of this kind should be quite rare, and most DO NOT affect the ability to use 
your program, but simply reflect errors in disposing of older information that is no 
longer needed. They are an attempt to detect any problem, no matter how small, 
when it occurs, before it can propagate and become a bigger problem. 
We recommend saving your program on a regular basis, perhaps with the 
AUTOSAVE feature, in order to invoke the consistency checking. 
Program Load/Save Error 
These errors occur when a program is loaded or saved, and have the usual causes for 
failing to find or open a file. Check that:  
1. The file exists, the name is spelled correctly, you have read/write/delete privileges 
for the file, and if saving, that the file is writable. (In Windows Explorer, see the file, 
right click and choose Properties and see if the file is read-only.) 
2. If the file is on a network, make sure that the network accepts long file names if 
the file's name is not DOS compatible (8.3 format). 
3. If saving, that the disk has enough room to save the file. 
4. If the file is on a network, make sure that no one else is simultaneously using the 
file. 
Swapping Devices Error 
There is an error in attempting to interchange the addresses of two devices.  
Check that: 
1. One or both devices could be built-in, and therefore its address cannot be changed. 
2. The devices may be of two different address types, perhaps one is a card and the 
other is a network device, and they cannot be interchanged. 
Error in Moving a Device 
There is an error in attempting to interchange the addresses of two devices. 
Check that: 
1. The device could be built-in, and therefore its address cannot be changed. 
2. You may be trying to move the device to a different address type. 
Perhaps it is a card and is moving to a network address, and that cannot be allowed. 
3. There may be a limitation on the address range of the device. For example, the 
CNIORACK has only one settable hexadecimal digit for an address, and must reside 
in network address range 03-0F. 
AutoFill Error 
Make sure that your control system is connected via its "computer port" to your PC's 
serial port. Drag and drop a control system of the appropriate type to the 
Configuration Manager, then select Autofill.  
182 
 Crestron SIMPL Windows 
Installation & Operations Guide – DOC. 5728C