 Cabinet/countertop depth is at discretion of customer but 
cabinet face MUST NOT protrude further than rear of front 
panel, see product dimensions.
4
 Consult local code for exact location requirements.
5
 Not applicable for cabinets more than a horizontal 
distance of 10” (254mm) from the edge of the range.
1
 Vertical to combustibles directly above cooking surface; 
if installing an overhead vent hood, also check the hood 
specifications for minimum required clearances. 
2
 Measured from range top panel.
Non-combustible
surface along 
back wall
recommended
30” (762mm)
Min.
1
36 1/2” 
(927mm)
Max.
13” (330mm)
Max.
5
Suggested
location of 
utilities
4
Planning the Installation
Cabinet Layout
Carefully check the location where the range is to be 
installed. For best performance, the range should be placed 
away from drafts that may be caused by doors, windows and 
heating and air conditioning outlets.
To reduce the risk of personal injury and to reduce 
accumulated smoke in the room, Dacor strongly recommends 
installing a range hood. A range hood should project 
horizontally a minimum of 5 inches beyond the face of the 
cabinets.
All maximum and minimum dimensions and clearances 
shown in the diagrams below must be maintained for safe 
operation.
The range may be installed flush to the rear wall.  
Dacor strongly recommends installing a non-combustible 
material on the rear wall above the range and up to the vent 
hood or installation of a backguard. It is not necessary to 
install non-combustible materials behind the range below the 
countertop height. 
Any openings in the wall behind the appliance or in the floor 
underneath it must be sealed.
CUT-OUT DIMENSIONS
Range Model
F
G
H
ER36D
42” (1067mm)* 
36” (914mm)**
36 1/16” 
(916mm)**
33 ½” 
(848mm)
ER48D
54” (1372mm)* 
48” (1219mm)**
48 1/16” 
(1221mm)**
43 ½” 
(1102mm)
* Recommended   **Minimum
All tolerances: +1/16”, -0 (+1.6mm, -0) 
Unless otherwise stated
Gas and Electrical Service
The shaded area shown denotes the location of the gas 
inlet and the electrical junction box/receptacle. This is the 
recommended location. For replacement purposes, the 
location of the existing utilities may be utilized provided they 
do not interfere with the sides or rear of the range. Check 
local building codes for permissible gas valve locations.
An external manual shut-off valve must be installed between 
the gas inlet and the range, for the purpose of turning on or 
shutting off gas to the appliance. 
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed. 
Access to the remote circuit breaker panel/fuse box, when the 
range is in place.  
The gas supply piping and shut-off valve, and the electrical 
junction box/receptacle must be located so they do not 
interfere with the range when it is installed.
The junction box and gas shut off valve must be located 
so that the range can be pulled out for service while the 
appliance remains connected. 

G
10" (254 mm) Min.
to combustible side
walls above the range
(both sides)
non-combustible
Minumum  Countertop Height:
30 1/4” (768 mm) 
Maximum  Countertop Height:
36 1/2” (927 mm)
rear wall recommended
Backsplash
3/8" (10 mm)
Min. flat countertop
overhang
H
2 13/16"
(71.4 mm)
3
Cutout with Optional ERv Raised vent (Top view)
Standard Cutout with 
Range Hood
APPROVED RAISED VENT MODEL NUMBERS
Range Model
ERV Raised Vent Model
ER36D
ERV36-ER
ER48D
ERV48-ER
IMPORTANT: See the raised vent installation instructions 
for the duct and electrical installation requirements. Use 
only the raised vent models specified below.