29
COMMAND
PARAMETER
(min/max)
Value stored?
DESCRIPTION
!STORE
NA
YES
Stores the current set of values 
(all values) into non-volatile 
memory 
!RESTORE
NA
YES
Restores the stored values
!FACTORY
NA
YES
Restores all values to factory 
default levels
!STATUS
NA
NA
Asks the Controller to provide 
the hardware information,
current values and system status
to the automation system 
!RESTART
NA
NO
Restarts the PFP Controller
(same as turning it on and off)
!ECHO
NA
NO
Enables the Controller to echo 
back commands and values to 
the automation system
!NOECHO
NA
NO
Disables the PFP Controller's
character echoing
!INSTALLMODEOFF
NA
NA
Disables the Installation menu 
(removes it from the main menu)
!INSTALLMODEON
NA
NA
Enables the Installation menu 
(enables it on the main menu)
!SERVICEMODEON
NA
NA
Enables the service mode
!SERVICEMODEOFF
NA
NA
Disable the service mode
RGAIN
-64/64
NO
Adjust the Red Gain of image
GGAIN
-64/64
NO
Adjust the Green Gain of image
BGAIN
-64/64
NO
Adjust the Blue Gain of image
ROFFSET
-64/64
NO
Adjust the amount of Red in the 
dark areas of the image
GOFFSET
-64/64
NO
Adjust the amount of Green in 
the dark areas of the image
BOFFSET
-64/64
NO
Adjust the amount of Blue in 
the dark areas of the image