Runco widevision cx-opal42 用户手册

下载
页码 84
Crystal Series LCD Installation/Operation Manual
39 
PRE
L
IMINAR
Y
Sleep Timer: Use the Sleep Timer to turn off the Crystal Series LCD after a specified 
interval.
To set the Sleep Timer:
• Select Sleep Timer from the Timer menu and press ENTER
– OR –
• Press the TIMER OFF button on the remote control. 
Use the right- or left-arrow button to select 10, 30, 60, 120 or 180 minutes. Then, press 
ENTER or MENU
Use the controls in the Setup menu to perform advanced image quality adjustments and 
access various other Crystal Series LCD features.
OSD Language: Select OSD Language from the Setup menu and press ENTER. Then, 
use the up- or down-arrow buttons to select the OSD language (English, French, Spanish, 
Portuguese or German). Press ENTER again to confirm your selection. 
OSD Timer: Use the 
 or 
 button to set the OSD Timer. This timer controls how long 
the menus remain on-screen after selecting them. Select from 0 to 60 seconds, in 
10-second increments. When you set the OSD to 0, the menus remain on-screen until 
you hide them by pressing EXIT
PC Mode Adjust: To improve the quality of displayed images from a computer or other 
VESA-compliant, RGB (480p or higher) source, select PC Mode Adjust and press 
ENTER
• Auto Adjust: Auto Adjust automatically adjusts settings to optimize computer images. 
To execute Auto Adjust on command, select Auto Adjust and press ENTER
 
• Clock: Use the up- or down-arrow buttons ( 
 ) to highlight Clock. Then, use the 
right-arrow button ( 
 ) to increase the pixel clock rate; use the left-arrow button ( 
 
to decrease it. 
• Phase: Adjust the phase if the image shows shimmer or “horizontal noise.” Pixel phase 
adjusts the phase of the pixel sampling clock relative to the incoming signal. The effect 
of this control is similar to that of a tracking control on a VCR. 
For best results, use a good test pattern such as a smooth gray consisting of a clear 
pattern of black and white pixels, or a similar “half on, half off” graphic image. (You may 
notice that you can stabilize the image at more than one point. Use either setting in this 
case.)
• H  Position:  Use the up- or down-arrow buttons ( 
 ) to highlight H Position. Then, 
use the right-arrow button ( 
 ) to shift the image to the right; use the left-arrow button 
 ) to shift the image to the left. 
• V Position: Use the up- or down-arrow buttons ( 
 ) to highlight V Position. Then, 
use the right-arrow button ( 
 ) to shift the image up; use the left-arrow button ( 
 ) to 
shift the image down.
To restore the factory-default Clock, Phase and Position settings, select Factory Reset 
and press ENTER
Auto Adjust may take some time to complete, depending on the 
characteristics of the incoming signal. 
Note